BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

640-acre Bakken spacing unit

T148N R93W section 34

Spacing unit1 wells allowed · order 29847Moccasin Creek-Bakken

Unit facts

Formation
Bakken
Acres
640
Type
Spacing unit
Land described
T148N R93W section 34
Pool
Moccasin Creek-Bakken
Zone
Zone III
County
Dunn County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-04457e7e99499f49e706
Wells allowed by the latest linked order
1
Wells assigned to this unit
0
Pending permits inside
0
Balance under the allowance
-6
First linked order
Oct 15, 2009
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.2 two-mile laterals per 1,280 acres
Density drilled so far
6.57 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 3 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

Ironside 16-3TFHBloodaxe 16-3HMC 14-11 POLAR BEAR 34HMOCCASIN CREEK 4-3-34-3H3MOCCASIN CREEK 4-3-34-4HStratus 14-33HMOCCASIN CREEK 16-34H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
Ironside 16-3TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)5,356 ft52%
Bloodaxe 16-3HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,233 ft51%
MC 14-11 POLAR BEAR 34HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,205 ft35%
MOCCASIN CREEK 4-3-34-3H3DEVON ENERGY WILLISTON, L.L.C.Active (A)5,015 ft92%
MOCCASIN CREEK 4-3-34-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,935 ft88%
Stratus 14-33HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,494 ft46%
MOCCASIN CREEK 16-34HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,413 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13744Case 11610Extended the spacing unitPEAK ND, LLC
  2. Order 21370Case 19067Listed the unit in a pool zone table, 2 wells allowed
  3. Order 22125Case 19818Established the spacing unit, 2 wells allowedKODIAK OIL & GAS (USA) INC.
  4. Order 26815Case 24449Terminated the spacing unitWHITING OIL AND GAS CORP.
  5. Order 29847Case 27403Established the spacing unit, 1 well allowedRIMROCK OIL & GAS WILLISTON LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

16 other units share a surveyed well with this one; overlapping units are not additive.