Spacing unit · Dunn County
1,920-acre Bakken spacing unit
T147N R92W sections 11, 14, 23
Unit facts
- Formation
- Bakken
- Acres
- 1,920
- Type
- Spacing unit
- Land described
- T147N R92W sections 11, 14, 23
- Pool
- Twin Buttes-Bakken
- Zone
- Zone XI
- County
- Dunn County
- Surveyed wells inside
- 11
- Most wells operated by
- Devon Energy
- Unit id
dsu-04a3474db4789b0e79b6- Wells allowed by the latest linked order
- 2
- Wells assigned to this unit
- 0
- Pending permits inside
- 0
- Balance under the allowance
- -9
- First linked order
- May 17, 2017
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 8.23 two-mile laterals per 1,280 acres
- Density drilled so far
- 3.85 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| CHARGING EAGLE 15-14-11-4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,620 ft100% |
| CHARGING EAGLE 10-14-11-3H3 | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 7,708 ft100% |
| CHARGING EAGLE 10-14-11-2H3 | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 7,355 ft100% |
| CHARGING EAGLE 10-14-11-3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 7,289 ft100% |
| CHARGING EAGLE 10-14-11-2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 7,288 ft100% |
| CHARGING EAGLE 1-22-23H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 6,684 ft100% |
| CHARGING EAGLE 14-14-24-16H3 | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,156 ft47% |
| CHARGING EAGLE 14-14-10-2H3 | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 3,259 ft33% |
| CHARGING EAGLE 15-14-24-16H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 3,153 ft36% |
| CHARGING EAGLE 14-14-10-3H3 | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 1,985 ft19% |
| CHARGING EAGLE 14-14-10-2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 1,871 ft19% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 27714Case 25310Established the spacing unit, 1 well allowedWHITING OIL AND GAS CORP.
- Order 27714Case 25310Designated the spacing unitWHITING OIL AND GAS CORP.
- Order 29626Case 27179Designated the spacing unit, 2 wells allowedRIMROCK OIL & GAS WILLISTON LLC AN ORDER AMENDING THE FIELD RULES
- Order 29647Case 27200Established the spacing unit, 2 wells allowedRIMROCK OIL & GAS WILLISTON LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
14 other units share a surveyed well with this one; overlapping units are not additive.
- T147N R92W sections 14, 23 1,280-acre Bakken spacing unit
- T147N R92W sections 12, 13, 24 1,920-acre Bakken spacing unit
- T147N R92W sections 13, 24 1,280-acre Bakken spacing unit
- T147N R92W sections 10, 15, 22 1,920-acre Bakken spacing unit
- T147N R92W section 23 640-acre Bakken spacing unit
- T147N R92W sections 15, 22 1,280-acre Bakken spacing unit
- T147N R92W sections 23, 24 1,280-acre Bakken spacing unit
- T147N R92W sections 10, 11, 14, 15 2,560-acre Bakken spacing unit
- T147N R92W sections 11, 14 1,280-acre Bakken spacing unit
- T147N R92W sections 1, 2, 3, 10, 11, 12 3,840-acre Bakken spacing unit
- T147N R92W sections 22, 23, 26, 27 2,560-acre Bakken spacing unit
- T147N R92W sections 21, 22, 23 1,600-acre Bakken spacing unit
- T147N R92W sections 22, 23 1,280-acre Bakken spacing unit
- T147N R92W sections 10, 15 1,280-acre Bakken spacing unit