BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

960-acre Bakken spacing unit

T152N R104W sections 6, 7, 18

Spacing unit1 wells allowed · order 33954Briar Creek-Bakken

Unit facts

Formation
Bakken
Acres
960
Type
Spacing unit
Land described
T152N R104W sections 6, 7, 18
Pool
Briar Creek-Bakken
Zone
Zone II
County
Williams County
Surveyed wells inside
3
Most wells operated by
Kraken / Neptune / Zavanna
Unit id
dsu-05e59f314b637cf11697
Wells allowed by the latest linked order
1
Wells assigned to this unit
2
Pending permits inside
0
Balance under the allowance
-1
First linked order
Jan 22, 2025
Review note
later_order_likely_missing
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
4.23 two-mile laterals per 1,280 acres
Density drilled so far
4.17 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

Bregman 6-7-18 #2HBregman LE 6-7-18 #1HPOMPEY 17-18H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
Bregman 6-7-18 #2HKRAKEN OPERATING, LLCActive (A)18,030 ft100%
Bregman LE 6-7-18 #1HKRAKEN OPERATING, LLCActive (A)16,447 ft100%
POMPEY 17-18HMERCURY RESOURCES LLCActive (A)1,011 ft16%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 33903Case 31214Designated the spacing unitKRAKEN OPERATING, LLC,
  2. Order 33954Case 31258Established the spacing unit, 1 well allowedKRAKEN OPERATING, LLC
  3. Order 34201Case 31480Designated the spacing unitDEVON ENERGY WILLISTON, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

2 other units share a surveyed well with this one; overlapping units are not additive.