BBakken SubsurfaceNorth Dakota well index

Spacing unit · Mountrail County

1,280-acre Bakken spacing unit

T155N R92W sections 17, 20

Spacing unit8 wells allowed · order 35988Alger-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T155N R92W sections 17, 20
Pool
Alger-Bakken
Zone
Zone XI
County
Mountrail County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-07bce0c55d7bfdd7b010
Wells allowed by the latest linked order
8
Wells assigned to this unit
7
Pending permits inside
0
Balance under the allowance
+1
First linked order
Nov 5, 2008
Laterals that still fit (Nov 2026 method)
2 (1.9 two-mile equivalents)
Neighbourhood target density
9.15 two-mile laterals per 1,280 acres
Density drilled so far
6.79 per 1,280 acres

Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

CVANCARA 20-17 4TFHCVANCARA 20-17 2TFHCVANCARA 20-17 #7HCVANCARA 20-17 #6TFHCVANCARA 20-17 1-HCVANCARA 20-17 #5HCVANCARA 20-17 3H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
CVANCARA 20-17 4TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,893 ft100%
CVANCARA 20-17 2TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,850 ft100%
CVANCARA 20-17 #7HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,327 ft100%
CVANCARA 20-17 #6TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,023 ft100%
CVANCARA 20-17 1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,871 ft100%
CVANCARA 20-17 #5HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,773 ft100%
CVANCARA 20-17 3HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,540 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 12534Case 10596Established the spacing unitBRIGHAM OIL AND GAS, LP
  2. Order 12492Case 10560Designated the spacing unitOASIS PETROLEUM NORTH AMERICA LLC
  3. Order 14549Case 12297Designated the spacing unitBRIGHAM OIL & GAS, L.P.
  4. Order 14975Case 12714Designated the spacing unit, 3 wells allowedOASIS PETROLEUM NORTH AMERICA LLC
  5. Order 15028Case 12765Established the spacing unit, 3 wells allowedBRIGHAM OIL & GAS, L.P.
  6. Order 16284Case 14009Designated the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
  7. Order 17383Case 15135Established the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
  8. Order 17378Case 15130Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
  9. Order 17856Case 15610Designated the spacing unit, 8 wells allowedSLAWSON EXPLORATION CO., INC.
  10. Order 18076Case 15821Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, L.P.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

One other unit shares a surveyed well with this one; overlapping units are not additive.