Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T152N R97W sections 1, 12
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T152N R97W sections 1, 12
- Pool
- Westberg-Bakken
- Zone
- Zone VIII
- County
- McKenzie County
- Surveyed wells inside
- 13
- Most wells operated by
- Devon Energy
- Unit id
dsu-0b3d610a2fde5ebba6a2- Wells allowed by the latest linked order
- 12
- Wells assigned to this unit
- 11
- Pending permits inside
- 0
- Balance under the allowance
- -1
- First linked order
- Oct 12, 2012
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 9.68 two-mile laterals per 1,280 acres
- Density drilled so far
- 11.35 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| ROLLA STATE 152-97-1-12-10H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 12,321 ft100% |
| WAHUS STATE 152-97-12-1-12H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 11,711 ft100% |
| WAHUS 12-1F XE 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,322 ft100% |
| WAHUS 12-1 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,235 ft100% |
| WAHUS STATE 152-97-12-1-4H | DEVON ENERGY WILLISTON, L.L.C. | Plugged and abandoned (PA) | 11,093 ft100% |
| ROLLA STATE 152-97-1-12-2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,955 ft100% |
| ROLLA 152-97-1-12-13H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,927 ft100% |
| ROLLA 152-97-1-12-20HLW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,774 ft100% |
| ROLLA 152-97-1-12-6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,719 ft100% |
| WAHUS STATE 152-97-12-1-11H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,621 ft100% |
| WAHUS STATE 152-97-12-1-3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,535 ft100% |
| ROLLA 152-97-1-1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,164 ft100% |
| WAHUS 1-12H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,200 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 20121Case 17852Established the spacing unit, 6 wells allowedNEWFIELD PRODUCTION CO.
- Order 21017Case 18715Pooled all interests in the unitNEWFIELD PRODUCTION CO.
- Order 31199Case 28656Established the spacing unit, 12 wells allowedOVINTIV PRODUCTION INC.
- Order 33063Case 30450Designated the spacing unitGRAYSON MILL OPERATING, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
4 other units share a surveyed well with this one; overlapping units are not additive.
- T152N R97W section 1 640-acre Bakken spacing unit
- T152N R97W sections 1, 12 2,560-acre Bakken spacing unit
- T152N R97W sections 1, 2, 11, 12 2,560-acre Bakken spacing unit
- T152N R97W section 12 640-acre Bakken spacing unit