Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T151N R101W sections 13, 24
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T151N R101W sections 13, 24
- Pool
- Alexander-Bakken
- Zone
- Zone I
- County
- McKenzie County
- Surveyed wells inside
- 7
- Most wells operated by
- Devon Energy
- Unit id
dsu-0f2c60236b32b65e2d6a- Wells allowed by the latest linked order
- 8
- Wells assigned to this unit
- 6
- Pending permits inside
- 0
- Balance under the allowance
- +1
- First linked order
- Jun 13, 2011
- Laterals that still fit (Nov 2026 method)
- 2 (1.91 two-mile equivalents)
- Neighbourhood target density
- 8.03 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.35 per 1,280 acres
Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| TIMBER CREEK 13-24 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 12,968 ft100% |
| TIMBER CREEK 13-24 6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,133 ft100% |
| TIMBER CREEK 13-24 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,259 ft100% |
| TIMBER CREEK 13-24 1TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,251 ft100% |
| TIMBER CREEK 13-24 5H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,249 ft100% |
| TIMBER CREEK 13-24 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,543 ft100% |
| HEINZ 18-19 XW #1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 2,801 ft25% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 16343Case 14068Established the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
- Order 16343Case 14068Designated the spacing unitBRIGHAM OIL & GAS, L.P.
- Order 18727Case 16461Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
- Order 20255Case 17986Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, LP
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
4 other units share a surveyed well with this one; overlapping units are not additive.
- T151N R101W sections 13, 14, 23, 24 2,560-acre Bakken spacing unit
- T151N R100W sections 18, 19 1,280-acre Bakken spacing unit
- T151N R100W sections 17, 18, 19, 20 2,560-acre Bakken spacing unit
- T151N R101W sections 13, 24 2,560-acre Bakken spacing unit