Spacing unit · Williams County
1,920-acre Bakken spacing unit
T155N R102W sections 34, 35, 36
Unit facts
- Formation
- Bakken
- Acres
- 1,920
- Type
- Spacing unit
- Land described
- T155N R102W sections 34, 35, 36
- Pool
- Painted Woods-Bakken
- Zone
- Zone XI
- County
- Williams County
- Surveyed wells inside
- 3
- Most wells operated by
- Devon Energy
- Unit id
dsu-114facbdbdfc596153cc- Wells allowed by the latest linked order
- 5
- Wells assigned to this unit
- 0
- Pending permits inside
- 0
- Balance under the allowance
- +2
- First linked order
- Jul 17, 2025
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 6.04 two-mile laterals per 1,280 acres
- Density drilled so far
- 0.92 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| MONT 4-3502H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 5,048 ft50% |
| MONT 10-3601H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 4,708 ft47% |
| MONT 3-3403H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 4,583 ft48% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 34492Case 31756Established the spacing unit, 5 wells allowedDEVON ENERGY WILLISTON, L.L.C.
- Order 34511Case 31775Pooled all interests in the unitDEVON ENERGY WILLISTON, L.L.C.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
5 other units share a surveyed well with this one; overlapping units are not additive.
- T155N R102W sections 33, 34 2,560-acre Bakken spacing unit
- T155N R102W section 35 1,280-acre Bakken spacing unit
- T155N R102W section 34 1,280-acre Bakken spacing unit
- T155N R102W section 36 1,280-acre Bakken spacing unit
- T154N R102W sections 1, 2, 3 1,920-acre Bakken spacing unit