BBakken SubsurfaceNorth Dakota well index

Spacing unit · Mountrail County

1,280-acre Bakken spacing unit

T155N R92W sections 6, 7

Spacing unit8 wells allowed · order 35988Alger-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T155N R92W sections 6, 7
Pool
Alger-Bakken
Zone
Zone XI
County
Mountrail County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-1e2fa32561440632c267
Wells allowed by the latest linked order
8
Wells assigned to this unit
7
Pending permits inside
0
Balance under the allowance
+1
First linked order
Feb 5, 2010
Laterals that still fit (Nov 2026 method)
2 (1.91 two-mile equivalents)
Neighbourhood target density
8.68 two-mile laterals per 1,280 acres
Density drilled so far
6.96 per 1,280 acres

Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

ROSS-ALGER 6-7 #2TFHROSS-ALGER 6-7 3HROSS-ALGER 6-7 5HROSS-ALGER 6-7 4TFHROSS-ALGER 6-7 6HROSS-ALGER 6-7 7TFH-RROSS-ALGER 6-7 1-H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
ROSS-ALGER 6-7 #2TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)11,633 ft100%
ROSS-ALGER 6-7 3HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,249 ft100%
ROSS-ALGER 6-7 5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,220 ft100%
ROSS-ALGER 6-7 4TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,160 ft100%
ROSS-ALGER 6-7 6HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,093 ft100%
ROSS-ALGER 6-7 7TFH-RDEVON ENERGY WILLISTON, L.L.C.Active (A)9,975 ft100%
ROSS-ALGER 6-7 1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,968 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14171Case 11973Designated the spacing unitWHITING OIL & GAS CORP.
  2. Order 14297Case 12060Established the spacing unit, 1 well allowedBRIGHAM OIL & GAS, L.P.
  3. Order 15162Case 12895Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
  4. Order 16139Case 13855Designated the spacing unitBRIGHAM OIL & GAS, L.P.
  5. Order 16284Case 14009Designated the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
  6. Order 17383Case 15135Established the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
  7. Order 17856Case 15610Designated the spacing unit, 8 wells allowedSLAWSON EXPLORATION CO., INC.
  8. Order 18076Case 15821Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, L.P.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

One other unit shares a surveyed well with this one; overlapping units are not additive.