Spacing unit · Williams County
3,840-acre Bakken spacing unit
T154N R103W sections 25, 36
Unit facts
- Formation
- Bakken
- Acres
- 3,840
- Type
- Spacing unit
- Land described
- T154N R103W sections 25, 36
- Pool
- Painted Woods-Bakken
- Zone
- Zone XVI
- County
- Williams County
- Surveyed wells inside
- 10
- Most wells operated by
- DEVON ENERGY WILLISTON, L.L.C.
- Unit id
dsu-2bcac01b61c266055834- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 4.8 two-mile laterals per 1,280 acres
- Density drilled so far
- 3.12 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| MARTIN 32-36 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 15,633 ft100% |
| MARTIN 32-36 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 15,484 ft100% |
| MARTIN 32-36 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 15,002 ft100% |
| MARTIN 32-36 XS 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 14,990 ft100% |
| MARTIN 32-31 1-H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,744 ft100% |
| ROUND PRAIRIE 9-3625H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,709 ft100% |
| M. OLSON 20-29 1-H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 5,090 ft53% |
| M. OLSON 20-29 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,740 ft49% |
| M. OLSON 20-29 6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,593 ft48% |
| GATHMAN 30-19 #1-H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 4,473 ft47% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 33408Case 30749Established the spacing unitGRAYSON MILL OPERATING, LLC
- Order 33438Case 30779Pooled all interests in the unitGRAYSON MILL OPERATING, LLC
- Order 34492Case 31756Designated the spacing unitDEVON ENERGY WILLISTON, L.L.C.
- Order 35950Case 33000Designated the spacing unitOASIS PETROLEUM NORTH AMERICA LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
10 other units share a surveyed well with this one; overlapping units are not additive.
- T154N R102W sections 20, 29 1,280-acre Bakken spacing unit
- T154N R103W section 36 3,840-acre Bakken spacing unit
- T154N R103W sections 25, 36 1,280-acre Bakken spacing unit
- T154N R102W sections 19, 30 1,280-acre Bakken spacing unit
- T154N R103W section 36 1,920-acre Bakken spacing unit
- T154N R102W sections 20, 21, 28, 29, 32, 33 3,840-acre Bakken spacing unit
- T154N R102W sections 19, 20, 29, 30 2,560-acre Bakken spacing unit
- T154N R102W sections 31, 32 1,280-acre Bakken spacing unit
- T154N R103W sections 25, 26, 35, 36 2,560-acre Bakken spacing unit
- T154N R103W sections 24, 25 2,560-acre Bakken spacing unit