Spacing unit · Mountrail County
2,560-acre Bakken spacing unit
T155N R92W sections 27, 28, 33, 34
Unit facts
- Formation
- Bakken
- Acres
- 2,560
- Type
- Spacing unit
- Land described
- T155N R92W sections 27, 28, 33, 34
- Pool
- Alger-Bakken
- Zone
- Zone XXIV
- County
- Mountrail County
- Surveyed wells inside
- 12
- Most wells operated by
- Devon Energy
- Unit id
dsu-340fd2ce24985e4820de- Wells allowed by the latest linked order
- 2
- Wells assigned to this unit
- 0
- Pending permits inside
- 0
- Balance under the allowance
- -10
- First linked order
- Oct 24, 2014
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 9.22 two-mile laterals per 1,280 acres
- Density drilled so far
- 5.46 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| STROBECK 27-34 3TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,836 ft100% |
| STROBECK 27-34 #6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,830 ft100% |
| ANDERSON 28-33 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,820 ft100% |
| ANDERSON 28-33 4TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,761 ft100% |
| ANDERSON 28-33 2TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,648 ft100% |
| STROBECK 27-34 5TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,608 ft100% |
| STROBECK 27-34 #8TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,607 ft100% |
| STROBECK 27-34 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,599 ft100% |
| ANDERSON 28-33 1-H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,588 ft100% |
| STROBECK 27-34 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,469 ft100% |
| STROBECK 27-34 #7H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,365 ft100% |
| STROBECK 27-34 1-H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 9,109 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 23546Case 21242Designated the spacing unitOASIS PETROLEUM NORTH AMERICA LLC
- Order 24682Case 22347Established the spacing unitSTATOIL OIL AND GAS LP
- Order 25050Case 22715Pooled all interests in the unitSTATOIL OIL & GAS LP
- Order 34072Case 31372Listed the unit in a pool zone table, 2 wells allowedGRAYSON MILL OPERATING, LLC
- Order 35988Case 33038Designated the spacing unitSOGC, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
6 other units share a surveyed well with this one; overlapping units are not additive.
- T155N R92W sections 31, 32, 33 3,840-acre Bakken spacing unit
- T155N R92W sections 28, 29, 32, 33 2,560-acre Bakken spacing unit
- T155N R92W sections 28, 33 1,280-acre Bakken spacing unit
- T155N R92W sections 27, 34 1,280-acre Bakken spacing unit
- T155N R92W sections 26, 27, 34, 35 2,560-acre Bakken spacing unit
- T155N R92W sections 34, 35 2,560-acre Bakken spacing unit