BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,600-acre Bakken spacing unit

Footprint 37deacb8

Spacing unit4 wells allowed · order 36220Foreman Butte-Bakken

Unit facts

Formation
Bakken
Acres
1,600
Type
Spacing unit
Pool
Foreman Butte-Bakken
Zone
Zone VII
County
McKenzie County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-37deacb8e1245371f195
Wells allowed by the latest linked order
4
Wells assigned to this unit
4
Pending permits inside
0
Balance under the allowance
-3
First linked order
Apr 27, 2026
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
4.9 two-mile laterals per 1,280 acres
Density drilled so far
4.81 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

ALBERT NORTH 27-28-29 1HALBERT NORTH 27-28-29 3HALBERT NORTH 27-28-29 4HALBERT NORTH 27-28-29 2HTJELDE 29-32 1-HALBERT B. 27-34 1HSAFELY TRUST 28-33 #1-H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
ALBERT NORTH 27-28-29 1HDEVON ENERGY WILLISTON, L.L.C.Drilling (DRL)12,917 ft100%
ALBERT NORTH 27-28-29 3HDEVON ENERGY WILLISTON, L.L.C.Drilling (DRL)12,400 ft100%
ALBERT NORTH 27-28-29 4HDEVON ENERGY WILLISTON, L.L.C.Drilling (DRL)12,313 ft100%
ALBERT NORTH 27-28-29 2HDEVON ENERGY WILLISTON, L.L.C.Drilling (DRL)12,157 ft100%
TJELDE 29-32 1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,760 ft50%
ALBERT B. 27-34 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,578 ft48%
SAFELY TRUST 28-33 #1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,502 ft47%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 35417Case 32571Listed the unit in a pool zone table, 4 wells allowedWHITING OIL AND GAS CORP.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.