BBakken SubsurfaceNorth Dakota well index

Spacing unit · Mountrail County

1,280-acre Bakken spacing unit

T156N R93W section 34

Spacing unit8 wells allowed · order 35988Alger-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T156N R93W section 34
Pool
Alger-Bakken
Zone
Zone XI
County
Mountrail County
Surveyed wells inside
10
Most wells operated by
Devon Energy
Unit id
dsu-381da7627355896b7eac
Wells allowed by the latest linked order
8
Wells assigned to this unit
8
Pending permits inside
0
Balance under the allowance
-2
First linked order
Nov 5, 2008
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.64 two-mile laterals per 1,280 acres
Density drilled so far
8.63 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

VACHAL 3-34 #5TFHVACHAL 3-34 #8TFHVACHAL 3-34 2TFHVACHAL 3-34 #6HVACHAL 3-34 #7HVACHAL 3-34 1-HVACHAL 3-34 #3HVACHAL 3-34 #4TFHVACHAL 3-34F XW #1HESTHER HYNEK 3-2F XN 1H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
VACHAL 3-34 #5TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,991 ft100%
VACHAL 3-34 #8TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,873 ft100%
VACHAL 3-34 2TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,758 ft100%
VACHAL 3-34 #6HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,647 ft100%
VACHAL 3-34 #7HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,602 ft100%
VACHAL 3-34 1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,475 ft100%
VACHAL 3-34 #3HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,467 ft100%
VACHAL 3-34 #4TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,437 ft100%
VACHAL 3-34F XW #1HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,385 ft96%
ESTHER HYNEK 3-2F XN 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,738 ft48%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 12534Case 10596Established the spacing unitBRIGHAM OIL AND GAS, LP
  2. Order 12492Case 10560Designated the spacing unitOASIS PETROLEUM NORTH AMERICA LLC
  3. Order 16139Case 13855Designated the spacing unitBRIGHAM OIL & GAS, L.P.
  4. Order 16412Case 14137Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
  5. Order 16284Case 14009Designated the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
  6. Order 17383Case 15135Established the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
  7. Order 17856Case 15610Designated the spacing unit, 8 wells allowedSLAWSON EXPLORATION CO., INC.
  8. Order 18076Case 15821Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, L.P.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.