Spacing unit · Dunn County
1,280-acre Bakken spacing unit
T147N R93W sections 1, 12
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T147N R93W sections 1, 12
- Pool
- Moccasin Creek-Bakken
- Zone
- Zone XV
- County
- Dunn County
- Surveyed wells inside
- 7
- Most wells operated by
- Devon Energy
- Unit id
dsu-39912e1e0c0658ac80b0- Wells allowed by the latest linked order
- 14
- Wells assigned to this unit
- 7
- Pending permits inside
- 0
- Balance under the allowance
- +7
- First linked order
- Nov 30, 2009
- Laterals that still fit (Nov 2026 method)
- 1 (0.94 two-mile equivalents)
- Neighbourhood target density
- 8.86 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.89 per 1,280 acres
Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| BLACKHAWK 1-12HW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,477 ft100% |
| BLACKHAWK 1-12HB | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,416 ft100% |
| BLACKHAWK 1-12HA | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,376 ft100% |
| BLACK HAWK 1-12H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,097 ft100% |
| BLACKHAWK 1-12HD | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,072 ft100% |
| BLACKHAWK 1-12HY | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,046 ft100% |
| BLACKHAWK 1-12HZ | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,887 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 13838Case 11686Established the spacing unitZENERGY OPERATING CO., LLC.
- Order 17040Case 14765Designated the spacing unitMARATHON OIL CO.
- Order 17201Case 14951Established the spacing unit, 1 well allowedKODIAK OIL & GAS (USA) INC.
- Order 18008Case 15753Designated the spacing unitDAKOTA-3 E&P CO., LLC
- Order 17942Case 15687Designated the spacing unit, 7 wells allowedKODIAK OIL & GAS (USA) INC.
- Order 18220Case 15958Established the spacing unit, 7 wells allowedDAKOTA-3 E&P CO., LLC
- Order 19409Case 17141Pooled all interests in the unitWPX ENERGY WILLISTON, LLC
- Order 24022Case 21668Established the spacing unit, 14 wells allowedWPX ENERGY WILLISTON, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
2 other units share a surveyed well with this one; overlapping units are not additive.
- T148N R93W sections 35, 36 3,840-acre Bakken spacing unit
- T147N R93W sections 1, 12 1,280-acre Bakken spacing unit