BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T152N R98W sections 17, 18, 19, 20

Spacing unit1 wells allowed · order 24683Banks-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T152N R98W sections 17, 18, 19, 20
Pool
Banks-Bakken
Zone
Zone XVI
County
McKenzie County
Surveyed wells inside
18
Most wells operated by
Devon Energy
Unit id
dsu-45b4190d460a73ca4dc7
Wells allowed by the latest linked order
1
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-17
First linked order
Sep 26, 2014
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.68 two-mile laterals per 1,280 acres
Density drilled so far
8.74 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

CHERYL 17-20 #1HCHERYL 17-20 2TFHBEAUX 18-19 1HCHERYL 17-20 #7HCHERYL 17-20 #4HBEAUX 18-19 2TFHCHERYL 17-20 #5HBEAUX 18-19 7HBEAUX 18-19 3TFHCHERYL 17-20 XW #1TFHCHERYL 17-20 #8TFHCHERYL 17-20 #3TFHCHERYL 17-20 #6TFHCHERYL 17-20 #1H-RBEAUX 18-19 4HBEAUX 18-19 5TFHBEAUX 18-19 6HCHERYL 17-20 XE #1H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
CHERYL 17-20 #1HSTATOIL OIL & GAS LPPlugged and abandoned (PA)11,478 ft100%
CHERYL 17-20 2TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)11,027 ft100%
BEAUX 18-19 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,467 ft100%
CHERYL 17-20 #7HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,281 ft100%
CHERYL 17-20 #4HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,188 ft100%
BEAUX 18-19 2TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,166 ft100%
CHERYL 17-20 #5HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,164 ft100%
BEAUX 18-19 7HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,147 ft100%
BEAUX 18-19 3TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,079 ft100%
CHERYL 17-20 XW #1TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)10,078 ft100%
CHERYL 17-20 #8TFHDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)10,053 ft100%
CHERYL 17-20 #3TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,936 ft100%
CHERYL 17-20 #6TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,841 ft100%
CHERYL 17-20 #1H-RDEVON ENERGY WILLISTON, L.L.C.Active (A)9,809 ft100%
BEAUX 18-19 4HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,699 ft100%
BEAUX 18-19 5TFHDEVON ENERGY WILLISTON, L.L.C.Active (A)9,420 ft100%
BEAUX 18-19 6HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,275 ft100%
CHERYL 17-20 XE #1HDEVON ENERGY WILLISTON, L.L.C.Active (A)7,941 ft79%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 23187Case 20881Designated the spacing unitKODIAK OIL & GAS (USA) INC.
  2. Order 24683Case 22348Established the spacing unit, 1 well allowedSTATOIL OIL AND GAS LP
  3. Order 25065Case 22730Pooled all interests in the unitSTATOIL OIL & GAS LP
  4. Order 31430Case 28884Designated the spacing unitGRAYSON MILL OPERATING, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.