BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

3,840-acre Bakken spacing unit

T153N R103W sections 25, 26, 27, 34, 35, 36

Spacing unitSixmile-Bakken

Unit facts

Formation
Bakken
Acres
3,840
Type
Spacing unit
Land described
T153N R103W sections 25, 26, 27, 34, 35, 36
Pool
Sixmile-Bakken
Zone
Zone IV
County
Williams County
Surveyed wells inside
13
Most wells operated by
DEVON ENERGY WILLISTON, L.L.C.
Unit id
dsu-4721b5fff386dee6e463
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
4.72 two-mile laterals per 1,280 acres
Density drilled so far
5.8 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

FALCON 25-27F 5HRFALCON 25-27F 1HGRAND NATIONAL 34-36F 5HGRAND NATIONAL 34-36F 4HGRAND NATIONAL 34-36F 3HFALCON 25-27F 3HFALCON 25-27F 2HGRAND NATIONAL 34-36F 2HGRAND NATIONAL 34-36F 1HFALCON 25-27F 4HRHARDSCRABBLE 4-3427HHARDSCRABBLE 13-3526HHARDSCRABBLE 10-2536H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
FALCON 25-27F 5HRDEVON ENERGY WILLISTON, L.L.C.Active (A)18,013 ft100%
FALCON 25-27F 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)15,617 ft100%
GRAND NATIONAL 34-36F 5HDEVON ENERGY WILLISTON, L.L.C.Active (A)15,579 ft100%
GRAND NATIONAL 34-36F 4HDEVON ENERGY WILLISTON, L.L.C.Active (A)15,577 ft100%
GRAND NATIONAL 34-36F 3HDEVON ENERGY WILLISTON, L.L.C.Active (A)15,544 ft100%
FALCON 25-27F 3HDEVON ENERGY WILLISTON, L.L.C.Active (A)15,173 ft100%
FALCON 25-27F 2HDEVON ENERGY WILLISTON, L.L.C.Active (A)15,120 ft100%
GRAND NATIONAL 34-36F 2HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)14,936 ft100%
GRAND NATIONAL 34-36F 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)14,870 ft100%
FALCON 25-27F 4HRDEVON ENERGY WILLISTON, L.L.C.Active (A)14,493 ft100%
HARDSCRABBLE 4-3427HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,583 ft100%
HARDSCRABBLE 13-3526HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,447 ft100%
HARDSCRABBLE 10-2536HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,423 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 32687Case 30077Established the spacing unitGRAYSON MILL OPERATING, LLC
  2. Order 34541Case 31804Designated the spacing unitOASIS PETROLEUM NORTH AMERICA LLC
  3. Order 32705Case 30095Pooled all interests in the unitGRAYSON MILL OPERATING, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

7 other units share a surveyed well with this one; overlapping units are not additive.