BBakken SubsurfaceNorth Dakota well index

Spacing unit · Burke County

1,920-acre Bakken spacing unit

T160N R94W sections 22, 27, 34

Spacing unit3 wells allowed · order 35714North Tioga-Bakken

Unit facts

Formation
Bakken
Acres
1,920
Type
Spacing unit
Land described
T160N R94W sections 22, 27, 34
Pool
North Tioga-Bakken
Zone
Zone IX
County
Burke County
Surveyed wells inside
6
Most wells operated by
Continental Resources
Unit id
dsu-48f7a77f5b073aad6e65
Wells allowed by the latest linked order
3
Wells assigned to this unit
2
Pending permits inside
0
Balance under the allowance
-2
First linked order
Sep 15, 2022
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
4.53 two-mile laterals per 1,280 acres
Density drilled so far
3.52 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

Sibbern Federal 4-22HSibbern Federal 5-22H1SIBBERN 1-27HSIBBERN 2-27HMARUSKIE 1-22HMARUSKIE 2-22H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
Sibbern Federal 4-22HCONTINENTAL RESOURCES, INC.Active (A)15,508 ft100%
Sibbern Federal 5-22H1CONTINENTAL RESOURCES, INC.Active (A)15,283 ft100%
SIBBERN 1-27HCONTINENTAL RESOURCES, INC.Active (A)10,322 ft100%
SIBBERN 2-27HCONTINENTAL RESOURCES, INC.Active (A)10,277 ft100%
MARUSKIE 1-22HCONTINENTAL RESOURCES, INC.Active (A)4,668 ft48%
MARUSKIE 2-22HCONTINENTAL RESOURCES, INC.Temporarily abandoned (TA)4,562 ft49%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 32052Case 29482Established the spacing unit, 3 wells allowedCONTINENTAL RESOURCES, INC.
  2. Order 32060Case 29490Pooled all interests in the unitCONTINENTAL RESOURCES, INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.