Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T150N R99W sections 26, 35
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T150N R99W sections 26, 35
- Pool
- South Tobacco Garden-Bakken
- Zone
- Zone V
- County
- McKenzie County
- Surveyed wells inside
- 11
- Most wells operated by
- Devon Energy
- Unit id
dsu-4d92b3b6fb3d379cec98- Wells allowed by the latest linked order
- 9
- Wells assigned to this unit
- 11
- Pending permits inside
- 0
- Balance under the allowance
- -2
- First linked order
- Aug 19, 2010
- Review note
- over_allowance
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 8.28 two-mile laterals per 1,280 acres
- Density drilled so far
- 10.55 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| HOVLAND 26-35 7H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,665 ft100% |
| HOVLAND 150-99-26-35-4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,499 ft100% |
| HOVLAND 150-99-26-35-2H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 10,257 ft100% |
| HOVLAND 26-35 6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,257 ft100% |
| HOVLAND 150-99-26-35-3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,032 ft100% |
| HOVLAND 26-35 XW 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,937 ft100% |
| HOVLAND 26-35 5H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,927 ft100% |
| STAAL 150-99-26-35-1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,897 ft100% |
| HOVLAND 26-35 8H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,882 ft100% |
| HOVLAND 26-35 9H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,864 ft100% |
| HOVLAND 26-35 XE 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,819 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 14694Case 12438Established the spacing unit, 1 well allowedNEWFIELD PRODUCTION CO.
- Order 14694Case 12438Designated the spacing unitNEWFIELD PRODUCTION CO.
- Order 16008Case 13730Pooled all interests in the unitNEWFIELD PRODUCTION CO.
- Order 17335Case 15084Established the spacing unit, 5 wells allowedNEWFIELD PRODUCTION CO.
- Order 17335Case 15084Designated the spacing unitNEWFIELD PRODUCTION CO.
- Order 20649Case 18380Designated the spacing unit, 7 wells allowedNEWFIELD PRODUCTION CO.
- Order 33024Case 30411Established the spacing unit, 9 wells allowedGRAYSON MILL OPERATING, LLC
- Order 32879Case 30269Designated the spacing unit, 9 wells allowedGRAYSON MILL OPERATING, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
2 other units share a surveyed well with this one; overlapping units are not additive.
- T150N R99W sections 25, 26, 35, 36 2,560-acre Bakken spacing unit
- T150N R99W sections 26, 27, 34, 35 2,560-acre Bakken spacing unit