BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T149N R92W sections 22, 27

Spacing unit12 wells allowed · order 35852Heart Butte-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T149N R92W sections 22, 27
Pool
Heart Butte-Bakken
Zone
Zone XXXV
County
Dunn County
Surveyed wells inside
8
Most wells operated by
Devon Energy
DMR case / order on the footprint
11447 /
Unit id
dsu-4f6400710fa0b228cb9a
Wells allowed by the latest linked order
12
Wells assigned to this unit
8
Pending permits inside
0
Balance under the allowance
+4
First linked order
Sep 28, 2009
Laterals that still fit (Nov 2026 method)
1 (0.95 two-mile equivalents)
Neighbourhood target density
8.89 two-mile laterals per 1,280 acres
Density drilled so far
7.67 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

FBIR GUYBLACKHAWK 24X-27GFBIR GUYBLACKHAWK 24X-27HFBIR GUYBLACKHAWK 24X-27DFBIR GUYBLACKHAWK 24X-27CFBIR GUYBLACKHAWK 24X-27ERFBIR GUYBLACKHAWK 24X-27AFBIR GUYBLACKHAWK 24X-27FFBIR GUYBLACKHAWK 24X-27B1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
FBIR GUYBLACKHAWK 24X-27GDEVON ENERGY WILLISTON, L.L.C.Active (A)11,534 ft100%
FBIR GUYBLACKHAWK 24X-27HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,173 ft100%
FBIR GUYBLACKHAWK 24X-27DDEVON ENERGY WILLISTON, L.L.C.Active (A)10,153 ft100%
FBIR GUYBLACKHAWK 24X-27CDEVON ENERGY WILLISTON, L.L.C.Active (A)9,973 ft100%
FBIR GUYBLACKHAWK 24X-27ERDEVON ENERGY WILLISTON, L.L.C.Active (A)9,951 ft100%
FBIR GUYBLACKHAWK 24X-27ADEVON ENERGY WILLISTON, L.L.C.Active (A)9,895 ft100%
FBIR GUYBLACKHAWK 24X-27FDEVON ENERGY WILLISTON, L.L.C.Active (A)9,365 ft100%
FBIR GUYBLACKHAWK 24X-27BDEVON ENERGY WILLISTON, L.L.C.Active (A)9,309 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13568Case 11447Established the spacing unitXTO ENERGY INC.
  2. Order 13817Case 11669Designated the spacing unitQUESTAR EXPL. AND PROD. CO.
  3. Order 14375Case 12125Designated the spacing unitKODIAK OIL & GAS (USA) INC.
  4. Order 14494Case 12243Designated the spacing unit, 2 wells allowedPEAK NORTH DAKOTA, LLC
  5. Order 16640Case 14363Designated the spacing unit, 6 wells allowedENERPLUS RESOURCES (U.S.A.) INC.
  6. Order 17367Case 15119Established the spacing unit, 6 wells allowedXTO ENERGY INC.
  7. Order 18815Case 16549Pooled all interests in the unitXTO ENERGY INC.
  8. Order 17625Case 15379Designated the spacing unit, 4 wells allowedQEP ENERGY CO.
  9. Order 17625Case 15379Listed the unit in a pool zone table, 6 wells allowedQEP ENERGY CO.
  10. Order 18717Case 16451Designated the spacing unit, 6 wells allowedENERPLUS RESOURCES (U.S.A.) INC.
  11. Order 18222Case 15960Designated the spacing unit, 8 wells allowedDAKOTA-3 E&P CO., LLC
  12. Order 20494Case 18225Designated the spacing unit, 8 wells allowedKODIAK OIL & GAS (USA) INC.
  13. Order 21676Case 19373Established the spacing unit, 8 wells allowedXTO ENERGY INC.
  14. Order 26814Case 24448Designated the spacing unit, 8 wells allowedWHITING OIL AND GAS CORP.
  15. Order 26745Case 24378Designated the spacing unit, 12 wells allowedQEP ENERGY CO.
  16. Order 26872Case 24506Designated the spacing unit, 12 wells allowedQEP ENERGY CO.
  17. Order 27023Case 24659Established the spacing unit, 12 wells allowedXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

3 other units share a surveyed well with this one; overlapping units are not additive.