BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

2,560-acre Bakken spacing unit

T149N R94W sections 25, 26, 35, 36

Spacing unitPhaelens Butte-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T149N R94W sections 25, 26, 35, 36
Pool
Phaelens Butte-Bakken
Zone
Zone XX
County
Dunn County
Surveyed wells inside
22
Most wells operated by
ENERPLUS RESOURCES USA CORPORATION
Unit id
dsu-5883f3cd1b2902b8ad98
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.64 two-mile laterals per 1,280 acres
Density drilled so far
10.24 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

GROUPER 149-94-36D-25HBASS 149-94-36C-25HSHAD 149-94-36C-25HMINNOW 149-94-36C-25HMORAY 149-94-36C-25H-TFMINOT GRADY 26-35HDKudu 149-94-36D-25HMINOT GRADY 26-35HCCutthroat 149-94-36C-25H-TFMINOT GRADY 26-35HFMINOT GRADY 26-35HTMINOT GRADY 26-35HYMINOT GRADY 26-35HWLBLUEGILL 149-94-36C-25H-TFMINOT GRADY 26-35HZSPOTTED HORN 26-35HASPOTTED HORN 26-35HULSPOTTED HORN 26-35HWSPOTTED HORN 26-35HSTURGEON 149-94-36D-25H-TFSALMON 149-94-36D-25H-TFFOSSA 149-93-31D-30H-LL1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
GROUPER 149-94-36D-25HENERPLUS RESOURCES USA CORPORATIONActive (A)10,403 ft100%
BASS 149-94-36C-25HENERPLUS RESOURCES USA CORPORATIONActive (A)10,344 ft100%
SHAD 149-94-36C-25HENERPLUS RESOURCES USA CORPORATIONActive (A)10,336 ft100%
MINNOW 149-94-36C-25HENERPLUS RESOURCES USA CORPORATIONActive (A)10,100 ft100%
MORAY 149-94-36C-25H-TFENERPLUS RESOURCES USA CORPORATIONActive (A)10,073 ft100%
MINOT GRADY 26-35HDDEVON ENERGY WILLISTON, L.L.C.Active (A)10,070 ft100%
Kudu 149-94-36D-25HENERPLUS RESOURCES USA CORPORATIONActive (A)10,065 ft100%
MINOT GRADY 26-35HCDEVON ENERGY WILLISTON, L.L.C.Active (A)10,049 ft100%
Cutthroat 149-94-36C-25H-TFENERPLUS RESOURCES USA CORPORATIONActive (A)10,048 ft100%
MINOT GRADY 26-35HFDEVON ENERGY WILLISTON, L.L.C.Active (A)10,044 ft100%
MINOT GRADY 26-35HTDEVON ENERGY WILLISTON, L.L.C.Active (A)9,982 ft100%
MINOT GRADY 26-35HYDEVON ENERGY WILLISTON, L.L.C.Active (A)9,973 ft100%
MINOT GRADY 26-35HWLDEVON ENERGY WILLISTON, L.L.C.Active (A)9,970 ft100%
BLUEGILL 149-94-36C-25H-TFENERPLUS RESOURCES USA CORPORATIONActive (A)9,934 ft100%
MINOT GRADY 26-35HZDEVON ENERGY WILLISTON, L.L.C.Active (A)9,925 ft100%
SPOTTED HORN 26-35HADEVON ENERGY WILLISTON, L.L.C.Active (A)9,800 ft100%
SPOTTED HORN 26-35HULDEVON ENERGY WILLISTON, L.L.C.Active (A)9,792 ft100%
SPOTTED HORN 26-35HWDEVON ENERGY WILLISTON, L.L.C.Active (A)9,772 ft100%
SPOTTED HORN 26-35HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,734 ft100%
STURGEON 149-94-36D-25H-TFENERPLUS RESOURCES USA CORPORATIONActive (A)9,697 ft100%
SALMON 149-94-36D-25H-TFENERPLUS RESOURCES USA CORPORATIONActive (A)9,611 ft100%
FOSSA 149-93-31D-30H-LLENERPLUS RESOURCES USA CORPORATIONActive (A)5,447 ft54%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 24673Case 22338Designated the spacing unitEOG RESOURCES, INC.
  2. Order 25477Case 23146Established the spacing unitWPX ENERGY WILLISTON, LLC
  3. Order 25684Case 23341Pooled all interests in the unitWPX ENERGY WILLISTON, LLC
  4. Order 34153Case 31229Designated the spacing unitEOG RESOURCES, INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.