Spacing unit · Williams County
1,280-acre Bakken spacing unit
T157N R98W sections 27, 34
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T157N R98W sections 27, 34
- Pool
- Oliver-Bakken
- Zone
- Zone V
- County
- Williams County
- Surveyed wells inside
- 6
- Most wells operated by
- Kraken / Neptune / Zavanna
- Unit id
dsu-588fb6b1f88fc0f13ef0- Wells allowed by the latest linked order
- 14
- Wells assigned to this unit
- 6
- Pending permits inside
- 0
- Balance under the allowance
- +8
- First linked order
- May 19, 2011
- Laterals that still fit (Nov 2026 method)
- 2 (1.91 two-mile equivalents)
- Neighbourhood target density
- 7.3 two-mile laterals per 1,280 acres
- Density drilled so far
- 5.76 per 1,280 acres
Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| HOBART 34-27 #3H | KRAKEN OPERATING, LLC | Active (A) | 10,298 ft100% |
| HOBART 34-27 #4H | KRAKEN OPERATING, LLC | Active (A) | 10,276 ft100% |
| HOBART LW 34-27 #1H | KRAKEN OPERATING, LLC | Active (A) | 10,225 ft100% |
| HOBART 34-27 #5H | KRAKEN OPERATING, LLC | Active (A) | 10,199 ft100% |
| HOBART 34-27 #2H | KRAKEN OPERATING, LLC | Active (A) | 10,162 ft100% |
| HOBART 1-27H | KRAKEN OPERATING, LLC | Active (A) | 9,747 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 16055Case 13773Established the spacing unit, 1 well allowed
- Order 16055Case 13773Designated the spacing unit
- Order 16827Case 14549Established the spacing unit, 7 wells allowedCONTINENTAL RESOURCES, INC.
- Order 17562Case 15317Pooled all interests in the unitCONTINENTAL RESOURCES, INC.
- Order 21983Case 19677Established the spacing unit, 1 well allowedCONTINENTAL RESOURCES, INC.
- Order 21983Case 19677Listed the unit in a pool zone table, 7 wells allowedCONTINENTAL RESOURCES, INC.
- Order 24330Case 21997Designated the spacing unit
- Order 27876Case 25473Established the spacing unit, 14 wells allowedKRAKEN OIL & GAS, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
2 other units share a surveyed well with this one; overlapping units are not additive.
- T157N R98W sections 27, 28, 33, 34 2,560-acre Bakken spacing unit
- T157N R98W sections 26, 27, 34, 35 2,560-acre Bakken spacing unit