Spacing unit · Mountrail County
1,280-acre Bakken spacing unit
T152N R93W sections 25, 36
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T152N R93W sections 25, 36
- Pool
- Big Bend-Bakken
- Zone
- Zone XXIII
- County
- Mountrail County
- Surveyed wells inside
- 14
- Most wells operated by
- Slawson
- Unit id
dsu-5d6b134a4307adb60341- Wells allowed by the latest linked order
- 6
- Wells assigned to this unit
- 5
- Pending permits inside
- 0
- Balance under the allowance
- -8
- First linked order
- Dec 12, 2013
- Laterals that still fit (Nov 2026 method)
- 1 (0.95 two-mile equivalents)
- Neighbourhood target density
- 9.43 two-mile laterals per 1,280 acres
- Density drilled so far
- 8.94 per 1,280 acres
Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| Rainmaker Federal 8-25-36TFH | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 10,262 ft100% |
| Rainmaker Federal 5-25-36TFH | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 10,225 ft100% |
| Rainmaker Federal 6-25-36TFH | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 10,209 ft100% |
| Rainmaker Federal 7-25-36TFH | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 10,205 ft100% |
| RAINMAKER {FEDERAL} 10-36-25TF2H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 10,161 ft100% |
| Zephyr Federal 2-36H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 5,120 ft100% |
| Howitzer 3-25H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 5,067 ft100% |
| HOWITZER 1-25H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 5,057 ft100% |
| ZEPHYR FEDERAL 3-36H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 5,041 ft100% |
| Howitzer 4-25H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 5,009 ft100% |
| ZEPHYR FEDERAL 4-36H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 5,000 ft100% |
| ZEPHYR 1-36H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 4,996 ft100% |
| HOWITZER 2-25H | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 4,893 ft100% |
| HOWITZER {FEDERAL} 5 SLTFH | SLAWSON EXPLORATION COMPANY, INC. | Active (A) | 1,974 ft22% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 21993Case 19687Designated the spacing unit, 3 wells allowedSLAWSON EXPLORATION CO., INC.
- Order 22417Case 20112Established the spacing unit, 3 wells allowedSLAWSON EXPLORATION CO., INC.
- Order 24511Case 22177Designated the spacing unit, 6 wells allowedSLAWSON EXPLORATION CO., INC.
- Order 24606Case 22272Established the spacing unit, 6 wells allowedSLAWSON EXPLORATION CO., INC.
- Order 25542Case 23211Pooled all interests in the unitSLAWSON EXPLORATION CO., INC.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
8 other units share a surveyed well with this one; overlapping units are not additive.
- T152N R93W section 25 640-acre Bakken spacing unit
- T152N R93W sections 26, 27, 34, 35 2,560-acre Bakken spacing unit
- T152N R93W sections 26, 35 1,280-acre Bakken spacing unit
- T152N R93W sections 25, 26, 35, 36 2,560-acre Bakken spacing unit
- T152N R93W sections 25, 36 2,560-acre Bakken spacing unit
- T152N R93W section 26 640-acre Bakken spacing unit
- T152N R93W section 36 640-acre Bakken spacing unit
- T152N R93W section 35 640-acre Bakken spacing unit