Spacing unit · Williams County
2,560-acre Bakken spacing unit
T154N R101W sections 5, 6, 7, 8
Unit facts
- Formation
- Bakken
- Acres
- 2,560
- Type
- Spacing unit
- Land described
- T154N R101W sections 5, 6, 7, 8
- Pool
- Todd-Bakken
- Zone
- Zone VIII
- County
- Williams County
- Surveyed wells inside
- 15
- Most wells operated by
- DEVON ENERGY WILLISTON, L.L.C.
- Unit id
dsu-602b4f2a9869037dd0c7- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 6.59 two-mile laterals per 1,280 acres
- Density drilled so far
- 7.15 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| FIELD TRUST 7-6 5TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,985 ft100% |
| DAVE ARNSON 5-8 5H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,715 ft100% |
| FIELD TRUST 7-6 #7H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 10,631 ft100% |
| FIELD TRUST 7-6 #8TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,495 ft100% |
| DAVE ARNSON 8-5 XW 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,291 ft100% |
| ORVILLE 4-9 XW 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,281 ft100% |
| DAVE ARNSON 08-05 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,272 ft100% |
| FIELD TRUST 7-6 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,657 ft100% |
| DAVE ARNSON 5-8 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,602 ft100% |
| DAVE ARNSON 08-05 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,551 ft100% |
| FIELD TRUST 7-6 3TFH | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 9,542 ft100% |
| FIELD TRUST 7-6 1-H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 9,451 ft100% |
| FIELD TRUST 7-6 6H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 9,415 ft100% |
| DAVE ARNSON 8-5 1-H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,383 ft100% |
| FIELD TRUST 7-6 #2TFH | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 9,351 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 31933Case 29363Designated the spacing unitGRAYSON MILL OPERATING, LLC
- Order 31998Case 29427Established the spacing unitGRAYSON MILL OPERATING, LLC
- Order 32009Case 29438Pooled all interests in the unitGRAYSON MILL OPERATING, LLC
- Order 32450Case 29845Designated the spacing unitOASIS PETROLEUM NORTH AMERICA LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
3 other units share a surveyed well with this one; overlapping units are not additive.
- T154N R101W sections 6, 7 1,280-acre Bakken spacing unit
- T154N R101W sections 5, 8 1,280-acre Bakken spacing unit
- T154N R101W sections 4, 5, 8, 9 2,560-acre Bakken spacing unit