BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T148N R97W sections 26, 35

Spacing unit12 wells allowed · order 35872Lost Bridge-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T148N R97W sections 26, 35
Pool
Lost Bridge-Bakken
Zone
Zone XIII
County
Dunn County
Surveyed wells inside
5
Most wells operated by
XTO Energy
Unit id
dsu-609d831af9129ab2a756
Wells allowed by the latest linked order
12
Wells assigned to this unit
4
Pending permits inside
10
Balance under the allowance
+7
First linked order
Nov 25, 2008
Laterals that still fit (Nov 2026 method)
7 (6.68 two-mile equivalents)
Neighbourhood target density
11.13 two-mile laterals per 1,280 acres
Density drilled so far
4.52 per 1,280 acres

Room to drill: 7 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

BOOMER FEDERAL 34X-35HBOOMER FEDERAL 34X-35DBOOMER FEDERAL 34X-35GBOOMER 34X-35Hay Draw 148-97-27-34-2H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
BOOMER FEDERAL 34X-35HXTO ENERGY INCActive (A)9,921 ft100%
BOOMER FEDERAL 34X-35DXTO ENERGY INCActive (A)9,612 ft100%
BOOMER FEDERAL 34X-35GXTO ENERGY INCActive (A)9,557 ft100%
BOOMER 34X-35XTO ENERGY INCActive (A)9,358 ft100%
Hay Draw 148-97-27-34-2HENERPLUS RESOURCES USA CORPORATIONActive (A)9,307 ft91%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 12559Case 10450Established the spacing unit
  2. Order 12647Case 10484Designated the spacing unit
  3. Order 13371Case 11275Designated the spacing unitXTO ENERGY INC.
  4. Order 13857Case 11702Established the spacing unitXTO ENERGY INC.
  5. Order 14072Case 11885Designated the spacing unit, 2 wells allowedENCORE OPERATING, L.P.
  6. Order 14598Case 12346Established the spacing unit, 3 wells allowedXTO ENERGY INC.
  7. Order 14738Case 12481Pooled all interests in the unitXTO ENERGY INC.
  8. Order 18257Case 15994Designated the spacing unit, 8 wells allowedDENBURY ONSHORE, LLC
  9. Order 21013Case 18711Established the spacing unit, 8 wells allowedXTO ENERGY INC.
  10. Order 26927Case 24561Designated the spacing unit, 12 wells allowedXTO ENERGY INC.
  11. Order 27024Case 24660Established the spacing unit, 12 wells allowedXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.