BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

320-acre Bakken spacing unit

T149N R94W section 22

Spacing unit1 wells allowed · order 28313Phaelens Butte-Bakken

Unit facts

Formation
Bakken
Acres
320
Type
Spacing unit
Land described
T149N R94W section 22
Pool
Phaelens Butte-Bakken
Zone
Zone I
County
McKenzie County
Surveyed wells inside
8
Most wells operated by
Devon Energy
Unit id
dsu-68c8c394d39304b1624e
Wells allowed by the latest linked order
1
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-7
First linked order
Jan 21, 2010
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.03 two-mile laterals per 1,280 acres
Density drilled so far
7.89 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

LUCY LONE FIGHT 16-22HBADGER 22-21HZBEAVER 22-21HCBADGER 22-21HABEAVER 22-21HBBADGER 22-21HYBEAVER 22-21HXBEAVER 22-21HW1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
LUCY LONE FIGHT 16-22HDEVON ENERGY WILLISTON, L.L.C.Plugged and abandoned (PA)4,340 ft100%
BADGER 22-21HZDEVON ENERGY WILLISTON, L.L.C.Active (A)2,412 ft24%
BEAVER 22-21HCDEVON ENERGY WILLISTON, L.L.C.Active (A)2,368 ft24%
BADGER 22-21HADEVON ENERGY WILLISTON, L.L.C.Active (A)2,362 ft24%
BEAVER 22-21HBDEVON ENERGY WILLISTON, L.L.C.Active (A)2,352 ft23%
BADGER 22-21HYDEVON ENERGY WILLISTON, L.L.C.Active (A)2,315 ft23%
BEAVER 22-21HXDEVON ENERGY WILLISTON, L.L.C.Active (A)2,241 ft23%
BEAVER 22-21HWDEVON ENERGY WILLISTON, L.L.C.Active (A)2,226 ft22%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14065Case 11878Established the spacing unit, 2 wells allowedENCORE OPERATING, L.P.
  2. Order 14065Case 11878Designated the spacing unitENCORE OPERATING, L.P.
  3. Order 19511Case 17242Pooled all interests in the unitWPX ENERGY WILLISTON, LLC
  4. Order 28313Case 25898Established the spacing unit, 1 well allowedWPX ENERGY WILLISTON, LLC
  5. Order 34153Case 31229Designated the spacing unitEOG RESOURCES, INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.