Spacing unit · Golden Valley County
640-acre Bakken spacing unit
T143N R103W section 11
Unit facts
- Formation
- Bakken
- Acres
- 640
- Type
- Spacing unit
- Land described
- T143N R103W section 11
- Pool
- Morgan Draw-Bakken
- Zone
- Zone III
- County
- Golden Valley County
- Surveyed wells inside
- 1
- Most wells operated by
- XTO Energy
- Unit id
dsu-6e1398ed5100574096bf- Wells allowed by the latest linked order
- 1
- Wells assigned to this unit
- 1
- Pending permits inside
- 0
- Balance under the allowance
- 0
- First linked order
- Feb 7, 1992
- Laterals that still fit (Nov 2026 method)
- 2 (0.98 two-mile equivalents)
- Neighbourhood target density
- 5.57 two-mile laterals per 1,280 acres
- Density drilled so far
- 1.4 per 1,280 acres
Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. The county or basin value stands in for the target because fewer than eight developed units lie within 20 miles. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| MORGAN DRAW FEDERAL C 5 | XTO ENERGY INC | Plugged and abandoned (PA) | 7,251 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 6297Case 5441Established the spacing unitCONOCO INC.
- Order 6344Case 5485Pooled all interests in the unitCONOCO INC.
- Order 14178Case 11980Listed the unit in a pool zone table, 2 wells allowedWHITING OIL & GAS CORP.
- Order 23824Case 21482Established the spacing unit, 1 well allowedXTO ENERGY INC.
- Order 23824Case 21482Designated the spacing unitXTO ENERGY INC.
- Order 29703Case 27256Designated the spacing unit
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
One other unit shares a surveyed well with this one; overlapping units are not additive.
- T143N R103W sections 2, 11 640-acre Bakken spacing unit