Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T150N R98W sections 17, 20
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T150N R98W sections 17, 20
- Pool
- Siverston-Bakken
- Zone
- Zone X
- County
- McKenzie County
- Surveyed wells inside
- 6
- Most wells operated by
- Devon Energy
- Unit id
dsu-7ece4fe6e120c24506ad- Wells allowed by the latest linked order
- 14
- Wells assigned to this unit
- 6
- Pending permits inside
- 0
- Balance under the allowance
- +8
- First linked order
- Oct 24, 2008
- Laterals that still fit (Nov 2026 method)
- 4 (3.8 two-mile equivalents)
- Neighbourhood target density
- 9.08 two-mile laterals per 1,280 acres
- Density drilled so far
- 5.56 per 1,280 acres
Room to drill: 4 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| HOFFMANN 150-98-17-20-6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,025 ft100% |
| HOLM 150-98-17-20-4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,874 ft100% |
| HOFFMANN 150-98-17-20-10HLW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,864 ft100% |
| CHARLOTTE 150-98-17-20-1H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 9,620 ft100% |
| CHARLOTTE 150-98-17-20-2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,410 ft100% |
| HOLM 150-98-17-20-3H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 9,284 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 12378Case 10475Designated the spacing unitST. MARY LAND & EXPL. CO.
- Order 16109Case 13825Designated the spacing unitENCORE OPERATING, L.P.
- Order 16854Case 14576Designated the spacing unit, 5 wells allowedZENERGY, INC.
- Order 16915Case 14637Established the spacing unit, 5 wells allowedNEWFIELD PRODUCTION CO.
- Order 17333Case 15082Pooled all interests in the unitNEWFIELD PRODUCTION CO.
- Order 18162Case 15903Designated the spacing unit, 7 wells allowedSM ENERGY CO.
- Order 19553Case 17284Established the spacing unit, 7 wells allowedNEWFIELD PRODUCTION CO.
- Order 29394Case 26952Established the spacing unit, 14 wells allowedNEWFIELD PRODUCTION CO.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
2 other units share a surveyed well with this one; overlapping units are not additive.
- T150N R98W sections 16, 17, 20, 21 2,560-acre Bakken spacing unit
- T150N R98W sections 17, 18, 19, 20 2,560-acre Bakken spacing unit