Spacing unit · McKenzie County
640-acre Bakken spacing unit
T150N R94W sections 28, 33
Unit facts
- Formation
- Bakken
- Acres
- 640
- Type
- Spacing unit
- Land described
- T150N R94W sections 28, 33
- Pool
- Spotted Horn-Bakken
- Zone
- Zone III
- County
- McKenzie County
- Surveyed wells inside
- 5
- Most wells operated by
- Devon Energy
- Unit id
dsu-8604670762e7f3686ef0- Wells allowed by the latest linked order
- 3
- Wells assigned to this unit
- 3
- Pending permits inside
- 0
- Balance under the allowance
- -2
- First linked order
- Mar 1, 2011
- Laterals that still fit (Nov 2026 method)
- 2 (1.92 two-mile equivalents)
- Neighbourhood target density
- 10.26 two-mile laterals per 1,280 acres
- Density drilled so far
- 7.36 per 1,280 acres
Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| PHEASANT 33-28HZ | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,161 ft100% |
| PHEASANT 33-28HD | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,102 ft100% |
| GERALD HALE 33-28H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 9,239 ft100% |
| YOUNG BIRD 34-27HQL | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 8,815 ft90% |
| PHEASANT 33-28HTL | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 905 ft9% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 15369Case 13101Designated the spacing unit, 2 wells allowedEOG RESOURCES, INC.
- Order 16134Case 13850Established the spacing unit, 2 wells allowedZENERGY OPERATING CO., LLC
- Order 17487Case 15242Pooled all interests in the unitDAKOTA-3 E&P CO., LLC
- Order 17430Case 15185Designated the spacing unit, 3 wells allowedHELIS OIL AND GAS CO., LLC
- Order 19123Case 16853Established the spacing unit, 3 wells allowedDAKOTA-3 E&P CO., LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
7 other units share a surveyed well with this one; overlapping units are not additive.
- T150N R94W section 33 320-acre Bakken spacing unit
- T150N R94W sections 28, 33 640-acre Bakken spacing unit
- T150N R94W sections 28, 29, 32, 33 1,280-acre Bakken spacing unit
- T150N R94W sections 27, 28, 33, 34 1,280-acre Bakken spacing unit
- T150N R94W sections 26, 27, 34, 35 2,560-acre Bakken spacing unit
- T150N R94W sections 28, 33 1,280-acre Bakken spacing unit
- T150N R94W sections 27, 34 1,280-acre Bakken spacing unit