BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

2,560-acre Bakken spacing unit

T144N R96W sections 1, 2, 11, 12

Spacing unitMurphy Creek-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T144N R96W sections 1, 2, 11, 12
Pool
Murphy Creek-Bakken
Zone
Zone XIX
County
Dunn County
Surveyed wells inside
7
Most wells operated by
XTO ENERGY INC
Unit id
dsu-8b6efe94bf63284e4c37
Laterals that still fit (Nov 2026 method)
1 (0.97 two-mile equivalents)
Neighbourhood target density
6.33 two-mile laterals per 1,280 acres
Density drilled so far
2.02 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

KULISH 24-2HKULISH 21-11 HHANSON 11-12HSADOWSKY 44-1HHANSON 11X-12AHANSON 11X-12EHANSON 11X-12B1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
KULISH 24-2HXTO ENERGY INCActive (A)9,543 ft100%
KULISH 21-11 HXTO ENERGY INCActive (A)7,916 ft100%
HANSON 11-12HXTO ENERGY INCActive (A)6,881 ft59%
SADOWSKY 44-1HXTO ENERGY INCActive (A)5,541 ft100%
HANSON 11X-12AXTO ENERGY INCActive (A)4,616 ft48%
HANSON 11X-12EXTO ENERGY INCActive (A)4,423 ft47%
HANSON 11X-12BXTO ENERGY INCActive (A)4,301 ft46%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 24874Case 22540Established the spacing unitXTO ENERGY INC.
  2. Order 24942Case 22607Designated the spacing unitMARATHON OIL CO.
  3. Order 35805Case 32879Designated the spacing unitPHOENIX OPERATING LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

9 other units share a surveyed well with this one; overlapping units are not additive.