BBakken SubsurfaceNorth Dakota well index

Spacing unit · Mountrail County

640-acre Bakken spacing unit

T152N R92W sections 15, 16

Spacing unit2 wells allowed · order 34203Big Bend-Bakken

Unit facts

Formation
Bakken
Acres
640
Type
Spacing unit
Land described
T152N R92W sections 15, 16
Pool
Big Bend-Bakken
Zone
Zone IV
County
Mountrail County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-901619f5f18db7fa4872
Wells allowed by the latest linked order
2
Wells assigned to this unit
2
Pending permits inside
0
Balance under the allowance
-5
First linked order
Dec 15, 2021
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.04 two-mile laterals per 1,280 acres
Density drilled so far
9.11 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

Pennington 16-15HAPennington 16-15-14HZPennington 16-15-14HYPennington 16-15HBPENNINGTON 16-15HTEMPEST FEDERAL 1 SLHPennington 16-15HCL1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
Pennington 16-15HADEVON ENERGY WILLISTON, L.L.C.Active (A)10,713 ft100%
Pennington 16-15-14HZDEVON ENERGY WILLISTON, L.L.C.Active (A)10,361 ft67%
Pennington 16-15-14HYDEVON ENERGY WILLISTON, L.L.C.Active (A)10,342 ft67%
Pennington 16-15HBDEVON ENERGY WILLISTON, L.L.C.Active (A)9,896 ft100%
PENNINGTON 16-15HDEVON ENERGY WILLISTON, L.L.C.Active (A)2,987 ft54%
TEMPEST FEDERAL 1 SLHSLAWSON EXPLORATION COMPANY, INC.Active (A)2,380 ft53%
Pennington 16-15HCLDEVON ENERGY WILLISTON, L.L.C.Active (A)1,374 ft14%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 31432Case 28886Designated the spacing unit, 2 wells allowedSLAWSON EXPLORATION CO., INC.
  2. Order 31516Case 28965Established the spacing unit, 2 wells allowedWPX ENERGY WILLISTON, LLC
  3. Order 31524Case 28973Pooled all interests in the unitWPX ENERGY WILLISTON, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

13 other units share a surveyed well with this one; overlapping units are not additive.