Spacing unit · Mountrail County
2,560-acre Bakken spacing unit
T150N R92W sections 1, 2, 11, 12
Unit facts
- Formation
- Bakken
- Acres
- 2,560
- Type
- Spacing unit
- Land described
- T150N R92W sections 1, 2, 11, 12
- Pool
- Van Hook-Bakken
- Zone
- Zone VII
- County
- Mountrail County
- Surveyed wells inside
- 14
- Most wells operated by
- Devon Energy
- Unit id
dsu-903a72cbca63e7629de8- Wells allowed by the latest linked order
- 1
- Wells assigned to this unit
- 0
- Pending permits inside
- 0
- Balance under the allowance
- -13
- First linked order
- Aug 21, 2014
- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 8.73 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.39 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| OLSON 12-1HY | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,090 ft100% |
| OLSON 1-12HW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,073 ft100% |
| OLSON 12-1HC | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,060 ft100% |
| OLSON 12-1HX | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,991 ft100% |
| MASON 2-11HA | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,908 ft100% |
| OLSON 12-1HD | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,786 ft100% |
| MASON 2-11HWR | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,757 ft100% |
| MASON 2-11HX | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,702 ft100% |
| GEORGE EVANS 11-2HD | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,689 ft100% |
| GEORGE EVANS 11-2HC | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,541 ft100% |
| GEORGE EVANS 11-2HZ | DEVON ENERGY WILLISTON, L.L.C. | Plugged and abandoned (PA) | 9,538 ft100% |
| State of ND 10-3HI | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,232 ft93% |
| MASON 2-11H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,176 ft100% |
| OLSON 1-12H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 8,655 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 24838Case 22504Designated the spacing unitQEP ENERGY CO.
- Order 24878Case 22544Established the spacing unit, 1 well allowedWPX ENERGY WILLISTON, LLC
- Order 25678Case 23335Pooled all interests in the unitWPX ENERGY WILLISTON, LLC
- Order 35220Case 32449Designated the spacing unitSPOTTED HAWK DEVELOPMENT, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
4 other units share a surveyed well with this one; overlapping units are not additive.
- T150N R92W sections 2, 11 1,280-acre Bakken spacing unit
- T151N R92W section 36 3,840-acre Bakken spacing unit
- T150N R92W sections 2, 3, 10, 11 2,560-acre Bakken spacing unit
- T150N R92W sections 1, 12 1,280-acre Bakken spacing unit