BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T151N R98W sections 3, 4

Spacing unit12 wells allowed · order 27005Garden-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T151N R98W sections 3, 4
Pool
Garden-Bakken
Zone
Zone V
County
McKenzie County
Surveyed wells inside
8
Most wells operated by
XTO Energy
Unit id
dsu-9263bb71effaa093f27a
Wells allowed by the latest linked order
12
Wells assigned to this unit
8
Pending permits inside
1
Balance under the allowance
+4
First linked order
Jan 19, 2011
Laterals that still fit (Nov 2026 method)
1 (0.95 two-mile equivalents)
Neighbourhood target density
9.88 two-mile laterals per 1,280 acres
Density drilled so far
7.61 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. 1 more would fit the density but not the spacing rule. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

RINK 13X-4ERINK 12X-4CRINK 12X-4DRINK 13X-4ARINK 13X-4BRINK 13X-4FRINK 12X-4HRINK 12-4ESH1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
RINK 13X-4EXTO ENERGY INCActive (A)12,099 ft100%
RINK 12X-4CXTO ENERGY INCActive (A)11,448 ft100%
RINK 12X-4DXTO ENERGY INCActive (A)9,889 ft100%
RINK 13X-4AXTO ENERGY INCActive (A)9,780 ft100%
RINK 13X-4BXTO ENERGY INCActive (A)9,718 ft100%
RINK 13X-4FXTO ENERGY INCActive (A)9,658 ft100%
RINK 12X-4HXTO ENERGY INCActive (A)9,540 ft100%
RINK 12-4ESHXTO ENERGY INCActive (A)7,896 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 15013Case 12750Designated the spacing unit
  2. Order 16109Case 13825Established the spacing unit, 1 well allowedENCORE OPERATING, L.P.
  3. Order 16109Case 13825Designated the spacing unitENCORE OPERATING, L.P.
  4. Order 16150Case 13866Pooled all interests in the unitENCORE OPERATING L.P.
  5. Order 18253Case 15990Established the spacing unit, 7 wells allowedDENBURY ONSHORE, LLC
  6. Order 25540Case 23209Established the spacing unit, 12 wells allowedXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

2 other units share a surveyed well with this one; overlapping units are not additive.