BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T150N R100W sections 2, 3, 10, 11

Spacing unitSandrocks-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T150N R100W sections 2, 3, 10, 11
Pool
Sandrocks-Bakken
Zone
Zone VI
County
McKenzie County
Surveyed wells inside
18
Most wells operated by
DEVON ENERGY WILLISTON, L.L.C.
Unit id
dsu-9949b17e8c2303c0adae
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.17 two-mile laterals per 1,280 acres
Density drilled so far
6.12 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

BARRACUDA 150-100-2-11-6HBARRACUDA 150-100-2-11-8HBARRACUDA 150-100-2-11-7HBARRACUDA 150-100-11-2-4HBARRACUDA 150-100-11-2-2HBARRACUDA 150-100-11-2-3HRBARRACUDA 150-100-2-11-1HSANDERS N 150-100-9-10-7HLLOYD 34-3 1-HLLOYD 34-3 4HLLOYD 34-3 5HSANDERS N 150-100-9-10-6HSANDERS 150-100-9-10-4HSANDERS 150-100-9-10-3HSANDERS 150-100-9-10-1HSANDERS 150-100-9-10-2HLLOYD 34-3 2HLLOYD 34-3 #3H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
BARRACUDA 150-100-2-11-6HDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)13,202 ft100%
BARRACUDA 150-100-2-11-8HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)10,328 ft100%
BARRACUDA 150-100-2-11-7HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)10,179 ft100%
BARRACUDA 150-100-11-2-4HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,876 ft100%
BARRACUDA 150-100-11-2-2HDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)9,860 ft100%
BARRACUDA 150-100-11-2-3HRDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)9,653 ft100%
BARRACUDA 150-100-2-11-1HDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)9,509 ft100%
SANDERS N 150-100-9-10-7HKRAKEN OPERATING, LLCActive (A)5,545 ft47%
LLOYD 34-3 1-HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,148 ft52%
LLOYD 34-3 4HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,119 ft50%
LLOYD 34-3 5HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,112 ft50%
SANDERS N 150-100-9-10-6HKRAKEN OPERATING, LLCActive (A)5,082 ft50%
SANDERS 150-100-9-10-4HKRAKEN OPERATING, LLCActive (A)5,041 ft53%
SANDERS 150-100-9-10-3HKRAKEN OPERATING, LLCActive (A)5,040 ft53%
SANDERS 150-100-9-10-1HKRAKEN OPERATING, LLCActive (A)5,036 ft51%
SANDERS 150-100-9-10-2HKRAKEN OPERATING, LLCActive (A)5,035 ft53%
LLOYD 34-3 2HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,022 ft53%
LLOYD 34-3 #3HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,011 ft54%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 31849Case 29280Established the spacing unitOVINTIV PRODUCTION INC.
  2. Order 31872Case 29303Designated the spacing unitOVINTIV PRODUCTION INC.
  3. Order 33457Case 30797Designated the spacing unitMUREX PETROLEUM CORP.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.