BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

2,560-acre Bakken spacing unit

T148N R97W sections 28, 29, 32, 33

Spacing unit2 wells allowed · order 34673Haystack Butte-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T148N R97W sections 28, 29, 32, 33
Pool
Haystack Butte-Bakken
Zone
Zone XIV
County
Dunn County
Surveyed wells inside
18
Most wells operated by
Continental Resources
Unit id
dsu-9ac93d45d1eacd7f3a19
Wells allowed by the latest linked order
2
Wells assigned to this unit
0
Pending permits inside
0
Balance under the allowance
-16
First linked order
Feb 16, 2015
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.38 two-mile laterals per 1,280 acres
Density drilled so far
8.13 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

INGA FEDERAL 41X-29THORP FEDERAL 11X-28FTHORP FEDERAL 11X-28BThorp Federal 2-28HThorp Federal 8-28HThorp Federal 6-28HThorp Federal 1-28HSLThorp Federal 4-28HThorp Federal 7-28H1Thorp Federal 9-28HSL1Thorp Federal 3-28H1Thorp Federal 5-28H1INGA FEDERAL 41X-29HINGA FEDERAL 41X-29CTHORP FEDERAL 11X-28ATHORP FEDERAL 11X-28EINGA FEDERAL 41X-29DTilton Tree 3F ULW1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
INGA FEDERAL 41X-29XTO ENERGY INCPlugged and abandoned (PA)10,532 ft100%
THORP FEDERAL 11X-28FXTO ENERGY INCPlugged and abandoned (PA)10,463 ft100%
THORP FEDERAL 11X-28BXTO ENERGY INCPlugged and abandoned (PA)10,444 ft100%
Thorp Federal 2-28HCONTINENTAL RESOURCES, INC.Active (A)10,408 ft100%
Thorp Federal 8-28HCONTINENTAL RESOURCES, INC.Active (A)10,395 ft100%
Thorp Federal 6-28HCONTINENTAL RESOURCES, INC.Active (A)10,372 ft100%
Thorp Federal 1-28HSLCONTINENTAL RESOURCES, INC.Active (A)10,330 ft100%
Thorp Federal 4-28HCONTINENTAL RESOURCES, INC.Active (A)10,324 ft100%
Thorp Federal 7-28H1CONTINENTAL RESOURCES, INC.Active (A)10,288 ft100%
Thorp Federal 9-28HSL1CONTINENTAL RESOURCES, INC.Active (A)10,287 ft100%
Thorp Federal 3-28H1CONTINENTAL RESOURCES, INC.Active (A)10,281 ft100%
Thorp Federal 5-28H1CONTINENTAL RESOURCES, INC.Abandoned (AB)10,191 ft100%
INGA FEDERAL 41X-29HXTO ENERGY INCPlugged and abandoned (PA)10,013 ft100%
INGA FEDERAL 41X-29CXTO ENERGY INCPlugged and abandoned (PA)10,003 ft100%
THORP FEDERAL 11X-28AXTO ENERGY INCPlugged and abandoned (PA)9,873 ft100%
THORP FEDERAL 11X-28EXTO ENERGY INCPlugged and abandoned (PA)9,864 ft100%
INGA FEDERAL 41X-29DXTO ENERGY INCPlugged and abandoned (PA)9,504 ft100%
Tilton Tree 3F ULWBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)983 ft6%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 23480Case 21176Designated the spacing unitNEWFIELD PRODUCTION CO.
  2. Order 24505Case 22171Established the spacing unitXTO ENERGY INC.
  3. Order 26423Case 24080Designated the spacing unitBURLINGTON RESOURCES OIL & GAS CO. LP
  4. Order 27022Case 24658Established the spacing unit, 2 wells allowedXTO ENERGY INC.
  5. Order 27022Case 24658Designated the spacing unit, 14 wells allowedXTO ENERGY INC.
  6. Order 27839Case 25436Designated the spacing unit, 2 wells allowedXTO ENERGY INC.
  7. Order 30974Case 28511Pooled all interests in the unitXTO HOLDINGS, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

11 other units share a surveyed well with this one; overlapping units are not additive.