BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

3,840-acre Bakken spacing unit

T155N R97W sections 5, 6, 7, 8, 17, 18

Spacing unitDollar Joe-Bakken

Unit facts

Formation
Bakken
Acres
3,840
Type
Spacing unit
Land described
T155N R97W sections 5, 6, 7, 8, 17, 18
Pool
Dollar Joe-Bakken
Zone
Zone XVI
County
Williams County
Surveyed wells inside
22
Most wells operated by
CONTINENTAL RESOURCES, INC.
Unit id
dsu-a8828f3b5d77aa5369e7
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.33 two-mile laterals per 1,280 acres
Density drilled so far
5.46 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

COLUMBIA 5-5HSALEM 2-6HCOLUMBIA 2-5HCOLUMBIA FEDERAL 6-5HCOLUMBIA FEDERAL 7-5HSALEM 1-6HSALEM 3-6HCOLUMBIA 4-5HCOLUMBIA 1-5HSALEM 5-6H1SALEM 4-6HCOLUMBIA 3-5HHARTFORD 1-19HHARTFORD 2-19HHARTFORD 3-19HRALEIGH 3-20HRALEIGH 2-20H1RALEIGH 4-20HRALEIGH 5-20H1RALEIGH 6-20H1RALEIGH 7-20HRALEIGH 1-20H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
COLUMBIA 5-5HCONTINENTAL RESOURCES, INC.Active (A)11,294 ft100%
SALEM 2-6HCONTINENTAL RESOURCES, INC.Active (A)10,949 ft100%
COLUMBIA 2-5HCONTINENTAL RESOURCES, INC.Active (A)10,119 ft100%
COLUMBIA FEDERAL 6-5HCONTINENTAL RESOURCES, INC.Active (A)9,753 ft100%
COLUMBIA FEDERAL 7-5HCONTINENTAL RESOURCES, INC.Active (A)9,724 ft100%
SALEM 1-6HCONTINENTAL RESOURCES, INC.Active (A)9,707 ft100%
SALEM 3-6HCONTINENTAL RESOURCES, INC.Active (A)9,675 ft100%
COLUMBIA 4-5HCONTINENTAL RESOURCES, INC.Inactive (IA)9,650 ft100%
COLUMBIA 1-5HCONTINENTAL RESOURCES, INC.Inactive (IA)9,626 ft100%
SALEM 5-6H1CONTINENTAL RESOURCES, INC.Active (A)9,580 ft100%
SALEM 4-6HCONTINENTAL RESOURCES, INC.Active (A)9,543 ft100%
COLUMBIA 3-5HCONTINENTAL RESOURCES, INC.Active (A)9,537 ft100%
HARTFORD 1-19HCONTINENTAL RESOURCES, INC.Active (A)5,060 ft52%
HARTFORD 2-19HCONTINENTAL RESOURCES, INC.Active (A)5,050 ft47%
HARTFORD 3-19HCONTINENTAL RESOURCES, INC.Plugged and abandoned (PA)5,048 ft49%
RALEIGH 3-20HCONTINENTAL RESOURCES, INC.Active (A)5,047 ft60%
RALEIGH 2-20H1CONTINENTAL RESOURCES, INC.Active (A)5,041 ft60%
RALEIGH 4-20HCONTINENTAL RESOURCES, INC.Active (A)5,037 ft47%
RALEIGH 5-20H1CONTINENTAL RESOURCES, INC.Active (A)5,033 ft39%
RALEIGH 6-20H1CONTINENTAL RESOURCES, INC.Active (A)5,012 ft53%
RALEIGH 7-20HCONTINENTAL RESOURCES, INC.Active (A)5,012 ft52%
RALEIGH 1-20HCONTINENTAL RESOURCES, INC.Active (A)5,011 ft52%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 35003Case 32248Established the spacing unitCONTINENTAL RESOURCES, INC.
  2. Order 35027Case 32272Pooled all interests in the unitCONTINENTAL RESOURCES, INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

12 other units share a surveyed well with this one; overlapping units are not additive.