BBakken SubsurfaceNorth Dakota well index

Spacing unit · Mountrail County

2,560-acre Bakken spacing unit

T151N R93W sections 1, 12

Spacing unit2 wells allowed · order 34203Big Bend-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T151N R93W sections 1, 12
Pool
Big Bend-Bakken
Zone
Zone XLV
County
Mountrail County
Surveyed wells inside
19
Most wells operated by
Slawson
Unit id
dsu-ad00c8bc81d78296664c
Wells allowed by the latest linked order
2
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-17
First linked order
Mar 10, 2014
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.32 two-mile laterals per 1,280 acres
Density drilled so far
8.4 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

SNIPER {FEDERAL} 1 SLHSNIPER FEDERAL 7-6-7TFHStallion 5-1-12TFHSniper Federal 3-6-7HSniper Federal 4-6-7TFHSTALLION 7-1-12HSNIPER FEDERAL 6-6-7TFHSTALLION 3-1-12HSTALLION FEDERAL 5 SLTFHSTALLION 6-1-12TFHSTALLION 8-1-12TFHStallion 4-1-12TFHSNIPER FEDERAL 1-6-7HSNIPER (FEDERAL) 2-6-7HSNIPER FEDERAL 5-6-7TFHSTALLION 2-1-12HSTALLION 1-1-12HJericho Federal 1 SLHHunter Federal 1 SLH1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
SNIPER {FEDERAL} 1 SLHSLAWSON EXPLORATION COMPANY, INC.Active (A)10,694 ft100%
SNIPER FEDERAL 7-6-7TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)10,038 ft100%
Stallion 5-1-12TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)10,021 ft100%
Sniper Federal 3-6-7HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,979 ft100%
Sniper Federal 4-6-7TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)9,964 ft100%
STALLION 7-1-12HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,943 ft100%
SNIPER FEDERAL 6-6-7TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)9,914 ft100%
STALLION 3-1-12HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,908 ft100%
STALLION FEDERAL 5 SLTFHSLAWSON EXPLORATION COMPANY, INC.Active (A)9,904 ft100%
STALLION 6-1-12TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)9,881 ft100%
STALLION 8-1-12TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)9,867 ft100%
Stallion 4-1-12TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)9,843 ft100%
SNIPER FEDERAL 1-6-7HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,839 ft100%
SNIPER (FEDERAL) 2-6-7HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,713 ft100%
SNIPER FEDERAL 5-6-7TFHSLAWSON EXPLORATION COMPANY, INC.Active (A)9,667 ft100%
STALLION 2-1-12HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,403 ft100%
STALLION 1-1-12HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,322 ft100%
Jericho Federal 1 SLHSLAWSON EXPLORATION COMPANY, INC.Active (A)4,130 ft57%
Hunter Federal 1 SLHSLAWSON EXPLORATION COMPANY, INC.Active (A)1,588 ft16%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 22418Case 20113Established the spacing unit, 1 well allowedSLAWSON EXPLORATION CO., INC.
  2. Order 22418Case 20113Designated the spacing unitSLAWSON EXPLORATION CO., INC.
  3. Order 24511Case 22177Designated the spacing unit, 2 wells allowedSLAWSON EXPLORATION CO., INC.
  4. Order 24606Case 22272Established the spacing unit, 2 wells allowedSLAWSON EXPLORATION CO., INC.
  5. Order 25544Case 23213Pooled all interests in the unitSLAWSON EXPLORATION CO., INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

15 other units share a surveyed well with this one; overlapping units are not additive.