BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

960-acre Bakken spacing unit

T154N R104W sections 22, 23

Spacing unit1 wells allowed · order 32421Round Prairie-Bakken

Unit facts

Formation
Bakken
Acres
960
Type
Spacing unit
Land described
T154N R104W sections 22, 23
Pool
Round Prairie-Bakken
Zone
Zone II
County
Williams County
Surveyed wells inside
7
Most wells operated by
Devon Energy
Unit id
dsu-add8b31a0c2f9a679437
Wells allowed by the latest linked order
1
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-6
First linked order
Jan 8, 2010
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
3.87 two-mile laterals per 1,280 acres
Density drilled so far
4.58 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

SHORT PRAIRIE 4-2322HCUDA 15-27F 3HCUDA 15-27F 4HCUDA 14-26F 5HCUDA 14-26F 1HCUDA 14-26F 2HCUDA 14-26F XE 1H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
SHORT PRAIRIE 4-2322HDEVON ENERGY WILLISTON, L.L.C.Active (A)6,701 ft100%
CUDA 15-27F 3HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,267 ft34%
CUDA 15-27F 4HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,266 ft34%
CUDA 14-26F 5HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,258 ft34%
CUDA 14-26F 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,251 ft34%
CUDA 14-26F 2HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,244 ft34%
CUDA 14-26F XE 1HDEVON ENERGY WILLISTON, L.L.C.Active (A)1,936 ft12%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 13828Case 11680Established the spacing unitEOG RESOURCES, INC.
  2. Order 14666Case 12410Established the spacing unit, 1 well allowed
  3. Order 14666Case 12410Designated the spacing unit
  4. Order 18064Case 15809Pooled all interests in the unitEOG RESOURCES, INC.
  5. Order 20436Case 18167Established the spacing unit, 2 wells allowedEOG RESOURCES, INC.
  6. Order 32421Case 29813Established the spacing unit, 1 well allowedGRAYSON MILL OPERATING, LLC
  7. Order 32422Case 29814Designated the spacing unitGRAYSON MILL OPERATING, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

7 other units share a surveyed well with this one; overlapping units are not additive.