BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T153N R97W sections 6, 7

Spacing unit1 wells allowed · order 23187Banks-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T153N R97W sections 6, 7
Pool
Banks-Bakken
Zone
Zone III
County
McKenzie County
Surveyed wells inside
17
Most wells operated by
Chord / Enerplus / Oasis / Whiting
Unit id
dsu-b16c41f6178a02058f2c
Wells allowed by the latest linked order
1
Wells assigned to this unit
4
Pending permits inside
0
Balance under the allowance
-16
First linked order
Aug 19, 2010
Review note
later_order_likely_missing
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.92 two-mile laterals per 1,280 acres
Density drilled so far
10.76 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

WOLD 16-7HWOLD 16-7TFHWOLD 44-7-8HWOLD FEDERAL 44-7-7HWOLD FEDERAL 44-7-6TFXHWOLD FEDERAL 44-7-6XHWOLD FEDERAL 44-7-5TFXHWOLD FEDERAL 44-7-5XHWOLD FEDERAL 44-7-4TFXHWOLD FEDERAL 44-7-3TFXHWOLD FEDERAL 44-7-4XHWOLD FEDERAL 44-7-2TFHWOLD FEDERAL 44-7-3HWOLD FEDERAL 44-7-1TFHWOLD FEDERAL 44-7-2HWOLD FEDERAL 44-7-1HFRICK 24-8-1HU1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
WOLD 16-7HWHITING OIL AND GAS CORPORATIONActive (A)13,318 ft100%
WOLD 16-7TFHWHITING OIL AND GAS CORPORATIONActive (A)10,181 ft100%
WOLD 44-7-8HWHITING OIL AND GAS CORPORATIONActive (A)9,448 ft100%
WOLD FEDERAL 44-7-7HWHITING OIL AND GAS CORPORATIONActive (A)9,317 ft100%
WOLD FEDERAL 44-7-6TFXHWHITING OIL AND GAS CORPORATIONActive (A)8,458 ft77%
WOLD FEDERAL 44-7-6XHWHITING OIL AND GAS CORPORATIONActive (A)7,090 ft63%
WOLD FEDERAL 44-7-5TFXHWHITING OIL AND GAS CORPORATIONActive (A)7,049 ft54%
WOLD FEDERAL 44-7-5XHWHITING OIL AND GAS CORPORATIONActive (A)6,274 ft47%
WOLD FEDERAL 44-7-4TFXHWHITING OIL AND GAS CORPORATIONActive (A)6,012 ft48%
WOLD FEDERAL 44-7-3TFXHWHITING OIL AND GAS CORPORATIONActive (A)5,159 ft48%
WOLD FEDERAL 44-7-4XHWHITING OIL AND GAS CORPORATIONActive (A)5,087 ft46%
WOLD FEDERAL 44-7-2TFHWHITING OIL AND GAS CORPORATIONAbandoned (AB)4,888 ft48%
WOLD FEDERAL 44-7-3HWHITING OIL AND GAS CORPORATIONActive (A)4,672 ft46%
WOLD FEDERAL 44-7-1TFHWHITING OIL AND GAS CORPORATIONActive (A)4,471 ft42%
WOLD FEDERAL 44-7-2HWHITING OIL AND GAS CORPORATIONInactive (IA)4,259 ft45%
WOLD FEDERAL 44-7-1HWHITING OIL AND GAS CORPORATIONAbandoned (AB)3,976 ft44%
FRICK 24-8-1HUWHITING OIL AND GAS CORPORATIONActive (A)3,581 ft34%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14814Case 12555Established the spacing unit, 1 well allowedNORTH PLAINS ENERGY, LLC
  2. Order 14814Case 12555Designated the spacing unitNORTH PLAINS ENERGY, LLC
  3. Order 16803Case 14526Pooled all interests in the unitNORTH PLAINS ENERGY, LLC,
  4. Order 21744Case 19442Established the spacing unit, 5 wells allowedKODIAK OIL & GAS (USA) INC.
  5. Order 23187Case 20881Established the spacing unit, 1 well allowedKODIAK OIL & GAS (USA) INC.
  6. Order 31430Case 28884Designated the spacing unitGRAYSON MILL OPERATING, LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.