BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

1,280-acre Bakken spacing unit

T159N R100W sections 17, 18

Spacing unit7 wells allowed · order 35057Blue Ridge-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T159N R100W sections 17, 18
Pool
Blue Ridge-Bakken
Zone
Zone IV
County
Williams County
Surveyed wells inside
1
Most wells operated by
Hunt Oil
Unit id
dsu-b769b0e477bb7a254637
Wells allowed by the latest linked order
7
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
+6
First linked order
Jul 10, 2014
Laterals that still fit (Nov 2026 method)
2 (1.76 two-mile equivalents)
Neighbourhood target density
5.37 two-mile laterals per 1,280 acres
Density drilled so far
0.9 per 1,280 acres

Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

BLUE RIDGE 159-100-18-17H-11 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
BLUE RIDGE 159-100-18-17H-1HUNT OIL COMPANYActive (A)9,486 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 24320Case 21987Established the spacing unit, 1 well allowedHUNT OIL CO.
  2. Order 24320Case 21987Designated the spacing unitHUNT OIL CO.
  3. Order 25266Case 22934Pooled all interests in the unitHUNT OIL CO.
  4. Order 24561Case 22227Designated the spacing unitCRESCENT POINT ENERGY US CORP.
  5. Order 27171Case 24808Designated the spacing unit, 7 wells allowedCRESCENT POINT ENERGY US CORP.
  6. Order 27315Case 24924Established the spacing unit, 7 wells allowed

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

2 other units share a surveyed well with this one; overlapping units are not additive.