BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T151N R96W sections 14, 23

Spacing unit14 wells allowed · order 31139Camel Butte-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T151N R96W sections 14, 23
Pool
Camel Butte-Bakken
Zone
Zone II
County
McKenzie County
Surveyed wells inside
12
Most wells operated by
Burlington / Marathon
Unit id
dsu-ba6a73a493fabf0436d0
Wells allowed by the latest linked order
14
Wells assigned to this unit
11
Pending permits inside
0
Balance under the allowance
+2
First linked order
May 25, 2007
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.85 two-mile laterals per 1,280 acres
Density drilled so far
10.7 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

ANDERSON RANCH 1E MBHRADERMECHER 10-22HSL1ANDERSON RANCH 2B MBHANDERSON RANCH 2A TFHANDERSON RANCH 2C TFHANDERSON RANCH 3C-MBHANDERSON RANCH 1C MBHANDERSON RANCH 1D TFHANDERSON RANCH 3A-MBHANDERSON RANCH 3B-TFHANDERSON RANCH 11-14HBLEGEN RANCH 3D TFH-ULW1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
ANDERSON RANCH 1E MBHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)11,096 ft100%
RADERMECHER 10-22HSL1CONTINENTAL RESOURCES, INC.Active (A)10,479 ft100%
ANDERSON RANCH 2B MBHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)10,014 ft100%
ANDERSON RANCH 2A TFHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)9,955 ft100%
ANDERSON RANCH 2C TFHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)9,930 ft100%
ANDERSON RANCH 3C-MBHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)9,856 ft100%
ANDERSON RANCH 1C MBHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)9,794 ft100%
ANDERSON RANCH 1D TFHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)9,791 ft100%
ANDERSON RANCH 3A-MBHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)9,717 ft100%
ANDERSON RANCH 3B-TFHBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)9,695 ft100%
ANDERSON RANCH 11-14HBURLINGTON RESOURCES OIL & GAS COMPANY LPPlugged and abandoned (PA)9,368 ft100%
BLEGEN RANCH 3D TFH-ULWBURLINGTON RESOURCES OIL & GAS COMPANY LPActive (A)2,497 ft25%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 11099Case 9454Established the spacing unitBURLINGTON RESOURCES OIL & GAS CO. LP
  2. Order 11700Case 9933Pooled all interests in the unitBURLINGTON RESOURCES OIL & GAS CO. LP,
  3. Order 11704Case 9839Designated the spacing unit
  4. Order 12022Case 10176Established the spacing unitBURLINGTON RESOURCES OIL AND GAS CO. LP
  5. Order 13501Case 11397Designated the spacing unit
  6. Order 13994Case 11818Listed the unit in a pool zone table, 2 wells allowedBURLINGTON RESOURCES OIL & GAS CO. LP
  7. Order 18859Case 16590Designated the spacing unit, 7 wells allowedBURLINGTON RESOURCES OIL & GAS CO. LP
  8. Order 21112Case 18811Established the spacing unit, 7 wells allowedBURLINGTON RESOURCES OIL & GAS CO. LP
  9. Order 24162Case 21833Established the spacing unit, 14 wells allowedBURLINGTON RESOURCES OIL & GAS CO. LP

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

5 other units share a surveyed well with this one; overlapping units are not additive.