BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

2,560-acre Bakken spacing unit

T151N R99W sections 29, 30, 31, 32

Spacing unit2 wells allowed · order 34449Tobacco Garden-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T151N R99W sections 29, 30, 31, 32
Pool
Tobacco Garden-Bakken
Zone
Zone VII
County
McKenzie County
Surveyed wells inside
14
Most wells operated by
XTO Energy
Unit id
dsu-bf60beaab20a9eb3eb38
Wells allowed by the latest linked order
2
Wells assigned to this unit
0
Pending permits inside
0
Balance under the allowance
-12
First linked order
Mar 5, 2015
Laterals that still fit (Nov 2026 method)
1 (0.96 two-mile equivalents)
Neighbourhood target density
9.08 two-mile laterals per 1,280 acres
Density drilled so far
6.8 per 1,280 acres

Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

TOBACCO GARDEN 31X-29CThor 2-31-30HTOBACCO GARDEN 31-29SEHTOBACCO GARDEN 31X-29DThor 4-31-30HThor 5-31-30HThor 3-31-30HTOBACCO GARDEN 24X-32FTOBACCO GARDEN 24X-32ATOBACCO GARDEN 24X-32ETOBACCO GARDEN 31X-29CXDTOBACCO GARDEN 24X-32AXBTOBACCO GARDEN 24X-32BTHOR 1-31-30H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
TOBACCO GARDEN 31X-29CXTO ENERGY INCActive (A)12,418 ft100%
Thor 2-31-30HSLAWSON EXPLORATION COMPANY, INC.Active (A)11,046 ft100%
TOBACCO GARDEN 31-29SEHXTO ENERGY INCInactive (IA)10,919 ft100%
TOBACCO GARDEN 31X-29DXTO ENERGY INCActive (A)10,250 ft100%
Thor 4-31-30HSLAWSON EXPLORATION COMPANY, INC.Active (A)10,145 ft100%
Thor 5-31-30HSLAWSON EXPLORATION COMPANY, INC.Active (A)10,121 ft100%
Thor 3-31-30HSLAWSON EXPLORATION COMPANY, INC.Active (A)10,061 ft100%
TOBACCO GARDEN 24X-32FXTO ENERGY INCActive (A)10,052 ft100%
TOBACCO GARDEN 24X-32AXTO ENERGY INCActive (A)10,018 ft100%
TOBACCO GARDEN 24X-32EXTO ENERGY INCActive (A)9,860 ft100%
TOBACCO GARDEN 31X-29CXDXTO ENERGY INCActive (A)9,791 ft100%
TOBACCO GARDEN 24X-32AXBXTO ENERGY INCActive (A)9,726 ft100%
TOBACCO GARDEN 24X-32BXTO ENERGY INCActive (A)9,658 ft100%
THOR 1-31-30HSLAWSON EXPLORATION COMPANY, INC.Active (A)9,028 ft100%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 25942Case 23601Established the spacing unit, 2 wells allowedXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

2 other units share a surveyed well with this one; overlapping units are not additive.