Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T150N R98W sections 18, 19
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T150N R98W sections 18, 19
- Pool
- Siverston-Bakken
- Zone
- Zone X
- County
- McKenzie County
- Surveyed wells inside
- 7
- Most wells operated by
- Devon Energy
- Unit id
dsu-bf8af814951f5b5b7c3e- Wells allowed by the latest linked order
- 14
- Wells assigned to this unit
- 7
- Pending permits inside
- 0
- Balance under the allowance
- +7
- First linked order
- May 6, 2010
- Laterals that still fit (Nov 2026 method)
- 2 (1.9 two-mile equivalents)
- Neighbourhood target density
- 8.85 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.89 per 1,280 acres
Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| LAWLAR 150-98-18-19-3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,100 ft100% |
| LAWLAR 150-98-18-19-2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,562 ft99% |
| LAWLAR 150-98-18-19-4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,243 ft100% |
| HOFFMANN 150-98-17-20-5HLW | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,099 ft100% |
| HOFFMANN 150-98-18-19-10H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,955 ft100% |
| HOFFMANN 150-98-18-19-5H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,932 ft100% |
| HOFFMANN 150-98-18-19-1H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 9,659 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 14557Case 12305Established the spacing unit, 1 well allowedNEWFIELD PRODUCTION CO.
- Order 14557Case 12305Designated the spacing unitNEWFIELD PRODUCTION CO.
- Order 15792Case 13514Pooled all interests in the unitNEWFIELD PRODUCTION CO.
- Order 18104Case 15849Designated the spacing unitDENBURY ONSHORE, LLC
- Order 18162Case 15903Designated the spacing unit, 7 wells allowedSM ENERGY CO.
- Order 19300Case 17032Established the spacing unit, 7 wells allowedNEWFIELD PRODUCTION CO.
- Order 29394Case 26952Established the spacing unit, 14 wells allowedNEWFIELD PRODUCTION CO.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
2 other units share a surveyed well with this one; overlapping units are not additive.
- T150N R99W sections 13, 24 2,560-acre Bakken spacing unit
- T150N R98W sections 17, 18, 19, 20 2,560-acre Bakken spacing unit