BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

1,280-acre Bakken spacing unit

T149N R97W sections 13, 24

Spacing unit12 wells allowed · order 31567North Fork-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T149N R97W sections 13, 24
Pool
North Fork-Bakken
Zone
Zone VI
County
McKenzie County
Surveyed wells inside
6
Most wells operated by
XTO Energy
Unit id
dsu-c95febc998d5b244dc5d
Wells allowed by the latest linked order
12
Wells assigned to this unit
5
Pending permits inside
0
Balance under the allowance
+6
First linked order
Feb 15, 2008
Laterals that still fit (Nov 2026 method)
5 (4.72 two-mile equivalents)
Neighbourhood target density
10.15 two-mile laterals per 1,280 acres
Density drilled so far
5.18 per 1,280 acres

Room to drill: 5 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

BADLANDS FEDERAL 21X-13EBADLANDS FEDERAL 21X-13CBADLANDS FEDERAL 21X-13BBADLANDS FEDERAL 21X-13HBADLANDS FEDERAL 21X-13BADLANDS FEDERAL 21X-13AXD1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
BADLANDS FEDERAL 21X-13EXTO ENERGY INCActive (A)10,281 ft100%
BADLANDS FEDERAL 21X-13CXTO ENERGY INCActive (A)10,277 ft100%
BADLANDS FEDERAL 21X-13BXTO ENERGY INCActive (A)10,261 ft100%
BADLANDS FEDERAL 21X-13HXTO ENERGY INCActive (A)9,935 ft100%
BADLANDS FEDERAL 21X-13XTO ENERGY INCActive (A)9,842 ft100%
BADLANDS FEDERAL 21X-13AXDXTO ENERGY INCActive (A)3,616 ft36%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 11618Case 9869Established the spacing unitHEADINGTON OIL CO. LLC
  2. Order 11724Case 9949Pooled all interests in the unitHEADINGTON OIL CO. LLC
  3. Order 11875Case 10064Designated the spacing unitENCORE OPERATING, L.P.
  4. Order 18861Case 16592Designated the spacing unitBURLINGTON RESOURCES OIL & GAS CO. LP
  5. Order 18258Case 15995Designated the spacing unit, 8 wells allowedDENBURY ONSHORE, LLC
  6. Order 19057Case 16788Established the spacing unit, 8 wells allowedXTO ENERGY INC.
  7. Order 24940Case 22605Designated the spacing unit, 12 wells allowedBURLINGTON RESOURCES OIL & GAS CO. LP
  8. Order 25539Case 23208Established the spacing unit, 12 wells allowedXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

4 other units share a surveyed well with this one; overlapping units are not additive.