BBakken SubsurfaceNorth Dakota well index

Spacing unit · McKenzie County

640-acre Bakken spacing unit

T152N R96W section 21

Spacing unit2 wells allowed · order 33063Westberg-Bakken

Unit facts

Formation
Bakken
Acres
640
Type
Spacing unit
Land described
T152N R96W section 21
Pool
Westberg-Bakken
Zone
Zone II
County
McKenzie County
Surveyed wells inside
14
Most wells operated by
Devon Energy
Unit id
dsu-cccc38db495276b69293
Wells allowed by the latest linked order
2
Wells assigned to this unit
2
Pending permits inside
0
Balance under the allowance
-12
First linked order
Sep 28, 2010
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
10.11 two-mile laterals per 1,280 acres
Density drilled so far
12.17 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

ANDERSON STATE 152-96-16-21-20HWISNESS STATE 152-96-16-21-14HWISNESS STATE 152-96-16-21-5HWISNESS STATE 152-96-16-21-21HWISNESS STATE 152-96-16-21-6HANDERSON STATE 152-96-16-21-6HLWWISNESS 152-96-21-2HWISNESS 1-21HWISNESS STATE 152-96-21-16-10HROLFSRUD STATE 152-96-21-16-12HWISNESS STATE 152-96-21-16-11HROLFSRUD STATE 152-96-21-16-2HZWISNESS STATE 152-96-21-16-1HXLARSEN 152-96-16-21-5HLW1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
ANDERSON STATE 152-96-16-21-20HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,129 ft50%
WISNESS STATE 152-96-16-21-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,110 ft52%
WISNESS STATE 152-96-16-21-5HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,107 ft51%
WISNESS STATE 152-96-16-21-21HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,101 ft52%
WISNESS STATE 152-96-16-21-6HDEVON ENERGY WILLISTON, L.L.C.Active (A)5,092 ft52%
ANDERSON STATE 152-96-16-21-6HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)4,892 ft48%
WISNESS 152-96-21-2HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)4,878 ft100%
WISNESS 1-21HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,836 ft100%
WISNESS STATE 152-96-21-16-10HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,651 ft52%
ROLFSRUD STATE 152-96-21-16-12HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,601 ft50%
WISNESS STATE 152-96-21-16-11HDEVON ENERGY WILLISTON, L.L.C.Active (A)4,550 ft52%
ROLFSRUD STATE 152-96-21-16-2HZDEVON ENERGY WILLISTON, L.L.C.Active (A)4,531 ft66%
WISNESS STATE 152-96-21-16-1HXDEVON ENERGY WILLISTON, L.L.C.Abandoned (AB)4,482 ft79%
LARSEN 152-96-16-21-5HLWDEVON ENERGY WILLISTON, L.L.C.Active (A)1,189 ft12%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14818Case 12559Established the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.
  2. Order 15464Case 13191Listed the unit in a pool zone table, 7 wells allowed
  3. Order 20121Case 17852Listed the unit in a pool zone table, 2 wells allowedNEWFIELD PRODUCTION CO.
  4. Order 20746Case 18460Established the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.
  5. Order 22848Case 20542Pooled all interests in the unitNEWFIELD PRODUCTION CO.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

6 other units share a surveyed well with this one; overlapping units are not additive.