BBakken SubsurfaceNorth Dakota well index

Spacing unit · Divide County

2,560-acre Bakken spacing unit

T163N R98W sections 32, 33

Spacing unitBlooming Prairie-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T163N R98W sections 32, 33
Pool
Blooming Prairie-Bakken
Zone
Zone XII
County
Divide County
Surveyed wells inside
10
Most wells operated by
FORMENTERA OPERATIONS, LLC
Unit id
dsu-cf48b9982ef4abd1e59d
Laterals that still fit (Nov 2026 method)
2 (1.91 two-mile equivalents)
Neighbourhood target density
4.67 two-mile laterals per 1,280 acres
Density drilled so far
2.45 per 1,280 acres

Room to drill: 2 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

HOLM 33-163-98HUNHJEM 5-162-98HSPARKS 4-162-98HNESS 3229-4HTROOPER 0409-3TFHTROOPER 0409-1TFHNESS 3229-6HCHARGER 0706-8HNESS 29-32-163-98HODYSSEY 0508-6H1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
HOLM 33-163-98HFORMENTERA OPERATIONS, LLCActive (A)5,901 ft100%
UNHJEM 5-162-98HFORMENTERA OPERATIONS, LLCActive (A)5,892 ft100%
SPARKS 4-162-98HFORMENTERA OPERATIONS, LLCActive (A)5,868 ft100%
NESS 3229-4HFORMENTERA OPERATIONS, LLCActive (A)5,336 ft51%
TROOPER 0409-3TFHFORMENTERA OPERATIONS, LLCActive (A)5,117 ft50%
TROOPER 0409-1TFHFORMENTERA OPERATIONS, LLCActive (A)5,061 ft50%
NESS 3229-6HFORMENTERA OPERATIONS, LLCActive (A)4,902 ft49%
CHARGER 0706-8HFORMENTERA OPERATIONS, LLCActive (A)4,692 ft49%
NESS 29-32-163-98HFORMENTERA OPERATIONS, LLCActive (A)4,679 ft50%
ODYSSEY 0508-6HFORMENTERA OPERATIONS, LLCActive (A)4,588 ft50%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 28156Case 25745Established the spacing unitRESOURCE ENERGY CAN-AM LLC
  2. Order 30621Case 28165Pooled all interests in the unitRESOURCE ENERGY CAN-AM LLC
  3. Order 33919Case 31230Designated the spacing unitFORMENTERA OPERATIONS LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

12 other units share a surveyed well with this one; overlapping units are not additive.