BBakken SubsurfaceNorth Dakota well index

Spacing unit · Dunn County

1,280-acre Bakken spacing unit

T148N R93W sections 8, 17

Spacing unit14 wells allowed · order 34228South Fork-Bakken

Unit facts

Formation
Bakken
Acres
1,280
Type
Spacing unit
Land described
T148N R93W sections 8, 17
Pool
South Fork-Bakken
Zone
Zone V
County
Dunn County
Surveyed wells inside
11
Most wells operated by
Devon Energy
Unit id
dsu-d6a716987e9e123aea85
Wells allowed by the latest linked order
14
Wells assigned to this unit
10
Pending permits inside
0
Balance under the allowance
+3
First linked order
Feb 19, 2010
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
9.44 two-mile laterals per 1,280 acres
Density drilled so far
9.35 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

SKUNK CREEK 4-8-17-13HSKUNK CREEK 2-8-17-15HSKUNK CREEK 4-8-17-13H3SKUNK CREEK 2-8-17-14H3SKUNK CREEK 4-8-17-14HSKUNK CREEK 4-8-17-14H3SKUNK CREEK 1-8-17-15HSKUNK CREEK 1-8-17-16HSKUNK CREEK 1-8-17-15H3SKUNK CREEK 1-8-17-16H3Right 148-93-05D-06H-LL1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
SKUNK CREEK 4-8-17-13HDEVON ENERGY WILLISTON, L.L.C.Active (A)10,263 ft100%
SKUNK CREEK 2-8-17-15HDEVON ENERGY WILLISTON, L.L.C.Inactive (IA)10,002 ft100%
SKUNK CREEK 4-8-17-13H3DEVON ENERGY WILLISTON, L.L.C.Active (A)9,766 ft100%
SKUNK CREEK 2-8-17-14H3DEVON ENERGY WILLISTON, L.L.C.Active (A)9,742 ft100%
SKUNK CREEK 4-8-17-14HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,628 ft100%
SKUNK CREEK 4-8-17-14H3DEVON ENERGY WILLISTON, L.L.C.Active (A)9,415 ft100%
SKUNK CREEK 1-8-17-15HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,404 ft100%
SKUNK CREEK 1-8-17-16HDEVON ENERGY WILLISTON, L.L.C.Active (A)9,097 ft100%
SKUNK CREEK 1-8-17-15H3DEVON ENERGY WILLISTON, L.L.C.Active (A)8,833 ft100%
SKUNK CREEK 1-8-17-16H3DEVON ENERGY WILLISTON, L.L.C.Active (A)8,747 ft100%
Right 148-93-05D-06H-LLENERPLUS RESOURCES USA CORPORATIONActive (A)3,191 ft34%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 14184Case 11986Established the spacing unit, 1 well allowedKODIAK OIL & GAS (USA) INC.
  2. Order 14214Case 12017Designated the spacing unitPEAK ND, LLC
  3. Order 14925Case 12631Designated the spacing unit
  4. Order 15481Case 13208Established the spacing unit, 4 wells allowedKODIAK OIL & GAS (USA) INC.
  5. Order 17938Case 15683Established the spacing unit, 6 wells allowedKODIAK OIL & GAS (USA) INC.
  6. Order 17984Case 15729Pooled all interests in the unitKODIAK OIL & GAS CORP.
  7. Order 20508Case 18239Pooled all interests in the unitKODIAK OIL & GAS CORP.
  8. Order 20884Case 18582Designated the spacing unit, 8 wells allowed
  9. Order 22940Case 20635Established the spacing unit, 8 wells allowedKODIAK OIL & GAS (USA) INC.
  10. Order 24023Case 21669Designated the spacing unit, 10 wells allowedWPX ENERGY WILLISTON, LLC
  11. Order 24660Case 22327Established the spacing unit, 10 wells allowedKODIAK OIL & GAS (USA) INC.
  12. Order 29275Case 26835Designated the spacing unit, 11 wells allowedRIMROCK OIL & GAS WILLISTON LLC
  13. Order 29294Case 26854Established the spacing unit, 11 wells allowedRIMROCK OIL & GAS WILLISTON LLC
  14. Order 30397Case 27945Established the spacing unit, 14 wells allowedRIMROCK OIL & GAS WILLISTON LLC

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

7 other units share a surveyed well with this one; overlapping units are not additive.