Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T151N R101W sections 2, 11
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T151N R101W sections 2, 11
- Pool
- Camp-Bakken
- Zone
- Zone VI
- County
- McKenzie County
- Surveyed wells inside
- 8
- Most wells operated by
- Devon Energy
- Unit id
dsu-d816f3b6397102ee7229- Wells allowed by the latest linked order
- 8
- Wells assigned to this unit
- 7
- Pending permits inside
- 0
- Balance under the allowance
- +1
- First linked order
- Jun 13, 2011
- Laterals that still fit (Nov 2026 method)
- 1 (0.95 two-mile equivalents)
- Neighbourhood target density
- 8.16 two-mile laterals per 1,280 acres
- Density drilled so far
- 6.85 per 1,280 acres
Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| EDNA 11-2 5TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,651 ft100% |
| EDNA 11-2 2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,593 ft100% |
| EDNA 11-2 7H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,224 ft100% |
| EDNA 11-2 3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,180 ft100% |
| EDNA 11-2 4TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,176 ft100% |
| EDNA 11-2 6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,175 ft100% |
| EDNA 11-2 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,956 ft100% |
| EDDIE B 1-2 SWD | ZENERGY, INC | Plugged and abandoned (PA) | 5,284 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 16343Case 14068Established the spacing unit, 4 wells allowedBRIGHAM OIL & GAS, L.P.
- Order 16047Case 13765Listed the unit in a pool zone table, 4 wells allowed
- Order 18309Case 16046Pooled all interests in the unitBRIGHAM OIL & GAS, L.P.
- Order 18107Case 15852Established the spacing unit, 7 wells allowedDENBURY ONSHORE, LLC
- Order 19837Case 17567Designated the spacing unit, 8 wells allowedCONTINENTAL RESOURCES, INC.
- Order 20256Case 17987Established the spacing unit, 8 wells allowedBRIGHAM OIL & GAS, L.P.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
One other unit shares a surveyed well with this one; overlapping units are not additive.
- T151N R101W sections 1, 2, 11, 12 2,560-acre Bakken spacing unit