Spacing unit · McKenzie County
1,280-acre Bakken spacing unit
T152N R97W sections 13, 24
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T152N R97W sections 13, 24
- Pool
- Westberg-Bakken
- Zone
- Zone IX
- County
- McKenzie County
- Surveyed wells inside
- 9
- Most wells operated by
- Devon Energy
- Unit id
dsu-dcd9cab04afb1a74c1b6- Wells allowed by the latest linked order
- 13
- Wells assigned to this unit
- 9
- Pending permits inside
- 0
- Balance under the allowance
- +4
- First linked order
- Dec 20, 2010
- Laterals that still fit (Nov 2026 method)
- 1 (0.95 two-mile equivalents)
- Neighbourhood target density
- 9.88 two-mile laterals per 1,280 acres
- Density drilled so far
- 8.57 per 1,280 acres
Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| DARLENE 13-24F 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,868 ft100% |
| DARLENE 13-24F 6TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,238 ft100% |
| WAHUS FEDERAL 152-97-13-24-4H | DEVON ENERGY WILLISTON, L.L.C. | Inactive (IA) | 10,214 ft100% |
| WAHUS FEDERAL 152-97-13-24-11H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 10,141 ft100% |
| DARLENE 13-24F 5TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,116 ft100% |
| WAHUS FEDERAL 152-97-13-24-1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,091 ft100% |
| DARLENE FEDERAL 152-97-13-24-2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,744 ft100% |
| DARLENE FEDERAL 152-97-13-24-3H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,536 ft100% |
| DARLENE FEDERAL 152-97-13-24-10H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 8,938 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 14819Case 12560Designated the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.
- Order 15041Case 12778Established the spacing unit, 2 wells allowedNEWFIELD PRODUCTION CO.
- Order 17299Case 15048Established the spacing unit, 6 wells allowedNEWFIELD PRODUCTION CO.
- Order 18331Case 16068Pooled all interests in the unitNEWFIELD PRODUCTION CO.
- Order 24413Case 22079Designated the spacing unit, 6 wells allowedHESS BAKKEN INVESTMENTS II, LLC
- Order 25072Case 22737Established the spacing unit, 8 wells allowedNEWFIELD PRODUCTION CO.
- Order 23722Case 21381Designated the spacing unit, 8 wells allowedCONTINENTAL RESOURCES, INC.
- Order 32323Case 29716Established the spacing unit, 13 wells allowedOVINTIV USA INC.
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
2 other units share a surveyed well with this one; overlapping units are not additive.
- T152N R97W sections 13, 24 2,560-acre Bakken spacing unit
- T152N R97W sections 13, 14, 23, 24 2,560-acre Bakken spacing unit