Spacing unit · McKenzie County
2,560-acre Bakken spacing unit
T153N R98W sections 26, 27, 34, 35
Unit facts
- Formation
- Bakken
- Acres
- 2,560
- Type
- Spacing unit
- Land described
- T153N R98W sections 26, 27, 34, 35
- Pool
- Banks-Bakken
- Zone
- Zone XVI
- County
- McKenzie County
- Surveyed wells inside
- 15
- Most wells operated by
- DEVON ENERGY WILLISTON, L.L.C.
- Unit id
dsu-dd64d913a310cab3efc0- Laterals that still fit (Nov 2026 method)
- 0
- Neighbourhood target density
- 9.56 two-mile laterals per 1,280 acres
- Density drilled so far
- 7.38 per 1,280 acres
Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| KNIGHT 35-26 2H | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 11,760 ft100% |
| KNIGHT 35-26F XE 1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,390 ft95% |
| KNIGHT 35-26 3TFH | DEVON ENERGY WILLISTON, L.L.C. | Abandoned (AB) | 11,339 ft100% |
| KNIGHT 35-26F 6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,269 ft100% |
| KNIGHT 35-26 4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,737 ft100% |
| MASTON 34-27 #7TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,665 ft100% |
| MASTON 34-27 #6H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,274 ft100% |
| MASTON 34-27 #8TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,145 ft100% |
| KNIGHT 35-26F 7TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 10,052 ft100% |
| MASTON 34-27 #1H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,807 ft100% |
| KNIGHT 35-26 #1-H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,722 ft100% |
| MASTON 34-27 #5TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,582 ft100% |
| MASTON 34-27 #2H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,527 ft100% |
| MASTON 34-27 #4H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,383 ft100% |
| MASTON 34-27 #3TFH | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,375 ft100% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 28986Case 26553Established the spacing unitSTATOIL OIL AND GAS LP
- Order 29154Case 26719Designated the spacing unitCONTINENTAL RESOURCES, INC.
- Order 31430Case 28884Designated the spacing unitGRAYSON MILL OPERATING, LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
4 other units share a surveyed well with this one; overlapping units are not additive.
- Footprint 04554162 1,280-acre Bakken spacing unit
- Footprint 3721f916 2,560-acre Bakken spacing unit
- T153N R98W sections 25, 26, 35, 36 2,560-acre Bakken spacing unit
- Footprint e417b85f 1,280-acre Bakken spacing unit