Spacing unit · Dunn County
1,280-acre Bakken spacing unit
T148N R92W sections 7, 8
Unit facts
- Formation
- Bakken
- Acres
- 1,280
- Type
- Spacing unit
- Land described
- T148N R92W sections 7, 8
- Pool
- Heart Butte-Bakken
- Zone
- Zone XXXIX
- County
- Dunn County
- Surveyed wells inside
- 9
- Most wells operated by
- Devon Energy
- Unit id
dsu-df0b20844b754ec9fd6d- Wells allowed by the latest linked order
- 14
- Wells assigned to this unit
- 8
- Pending permits inside
- 0
- Balance under the allowance
- +5
- First linked order
- Jul 22, 2011
- Laterals that still fit (Nov 2026 method)
- 1 (0.93 two-mile equivalents)
- Neighbourhood target density
- 9.03 two-mile laterals per 1,280 acres
- Density drilled so far
- 8.1 per 1,280 acres
Room to drill: 1 lateral still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.
Map
DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.
Wells inside the unit
| Well | Operator | Status | Lateral inside |
|---|---|---|---|
| SKUNK CREEK 12-7-8-8H3A | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 11,699 ft100% |
| SKUNK CREEK 12-7-8-9H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,752 ft100% |
| SKUNK CREEK 12-7-8-16HA | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,647 ft100% |
| SKUNK CREEK 12-7-8-16H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,629 ft100% |
| SKUNK CREEK 12-7-8-16H3 | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,551 ft100% |
| SKUNK CREEK 12-7-8-9H3A | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 9,471 ft100% |
| SKUNK CREEK 12-7-8-8H | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 8,784 ft100% |
| SKUNK CREEK 12-7-8-9H3 | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 8,597 ft100% |
| SKUNK CREEK 12-7-8-9HA | DEVON ENERGY WILLISTON, L.L.C. | Active (A) | 6,824 ft71% |
Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.
Order history
- Order 16640Case 14363Designated the spacing unit, 6 wells allowedENERPLUS RESOURCES (U.S.A.) INC.
- Order 16778Case 14501Established the spacing unit, 6 wells allowedKODIAK OIL & GAS (USA) INC.
- Order 20506Case 18237Pooled all interests in the unitKODIAK OIL & GAS CORP.
- Order 26057Case 23715Designated the spacing unit, 10 wells allowedSHD OIL & GAS, LLC
- Order 26335Case 23991Established the spacing unit, 10 wells allowedWHITING OIL AND GAS CORP.
- Order 28823Case 26397Designated the spacing unit, 14 wells allowedWPX ENERGY WILLISTON, LLC
- Order 29000Case 26567Established the spacing unit, 14 wells allowedRIMROCK OIL & GAS WILLISTON LLC
Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.
Overlapping units
5 other units share a surveyed well with this one; overlapping units are not additive.
- T148N R92W sections 5, 6, 7, 8 2,560-acre Bakken spacing unit
- T148N R93W sections 1, 12, 13 3,840-acre Bakken spacing unit
- T148N R92W sections 17, 18 1,280-acre Bakken spacing unit
- T148N R92W sections 7, 8, 17, 18 2,560-acre Bakken spacing unit
- T148N R92W sections 17, 18, 19, 20 2,560-acre Bakken spacing unit