BBakken SubsurfaceNorth Dakota well index

Spacing unit · Williams County

2,560-acre Bakken spacing unit

T154N R97W sections 13, 24

Spacing unit2 wells allowed · order 33838Grinnell-Bakken

Unit facts

Formation
Bakken
Acres
2,560
Type
Spacing unit
Land described
T154N R97W sections 13, 24
Pool
Grinnell-Bakken
Zone
Zone IV
County
Williams County
Surveyed wells inside
21
Most wells operated by
Continental Resources
Unit id
dsu-e190902c87a6eea910c2
Wells allowed by the latest linked order
2
Wells assigned to this unit
1
Pending permits inside
0
Balance under the allowance
-19
First linked order
Nov 21, 2013
Laterals that still fit (Nov 2026 method)
0
Neighbourhood target density
8.54 two-mile laterals per 1,280 acres
Density drilled so far
10.37 per 1,280 acres

Room to drill: 0 laterals still fit at the density this unit's neighbourhood has reached (the larger of the 75th percentile of mature units within 10 miles and the median of units drilled in the last three years), placed in the widest gaps with the setbacks of the November 2026 method. Machine-made and geometric: not a commitment to drill, not a permit, order, lease or plan, and no economics. Land is counted once, so a unit under a larger unit shows only what the larger one left. How it is computed.

Map

ARLEY 21X-18ECHERYL FEDERAL 24X-12AAMES FEDERAL 31X-13FXGCHERYL FEDERAL 24X-12ECHERYL FEDERAL 24X-12AXBArley 5-18HArley 6-18H1CHERYL FEDERAL 24X-12EXFARLEY 21X-18ASARA 41X-13HXEAMES FEDERAL 31X-13BAMES FEDERAL 31X-13FSARA 41X-13DXAAMES 31X-13CSARA 41X-13DARLEY 21X-18BAMES FEDERAL 31X-13BXCSARA 41X-13HARLEY 21X-18FSARA 41X-13GArley 7-18HSL1 mi

DMR footprint (NAD83) with the published surface locations of its wells. Laterals run under the unit; pads often sit on a neighbouring section.

Wells inside the unit

WellOperatorStatusLateral inside
ARLEY 21X-18ECONTINENTAL RESOURCES, INC.Active (A)16,945 ft100%
CHERYL FEDERAL 24X-12ACONTINENTAL RESOURCES, INC.Active (A)14,404 ft100%
AMES FEDERAL 31X-13FXGCONTINENTAL RESOURCES, INC.Inactive (IA)12,534 ft100%
CHERYL FEDERAL 24X-12ECONTINENTAL RESOURCES, INC.Active (A)10,515 ft100%
CHERYL FEDERAL 24X-12AXBCONTINENTAL RESOURCES, INC.Active (A)10,287 ft100%
Arley 5-18HCONTINENTAL RESOURCES, INC.Active (A)10,133 ft100%
Arley 6-18H1CONTINENTAL RESOURCES, INC.Active (A)10,114 ft100%
CHERYL FEDERAL 24X-12EXFCONTINENTAL RESOURCES, INC.Active (A)10,088 ft100%
ARLEY 21X-18ACONTINENTAL RESOURCES, INC.Active (A)10,031 ft100%
SARA 41X-13HXECONTINENTAL RESOURCES, INC.Abandoned (AB)9,969 ft100%
AMES FEDERAL 31X-13BCONTINENTAL RESOURCES, INC.Active (A)9,871 ft100%
AMES FEDERAL 31X-13FCONTINENTAL RESOURCES, INC.Active (A)9,787 ft100%
SARA 41X-13DXACONTINENTAL RESOURCES, INC.Abandoned (AB)9,739 ft100%
AMES 31X-13CCONTINENTAL RESOURCES, INC.Inactive (IA)9,683 ft100%
SARA 41X-13DCONTINENTAL RESOURCES, INC.Active (A)9,555 ft100%
ARLEY 21X-18BCONTINENTAL RESOURCES, INC.Active (A)9,495 ft100%
AMES FEDERAL 31X-13BXCCONTINENTAL RESOURCES, INC.Inactive (IA)9,479 ft100%
SARA 41X-13HCONTINENTAL RESOURCES, INC.Inactive (IA)9,451 ft100%
ARLEY 21X-18FCONTINENTAL RESOURCES, INC.Active (A)9,315 ft100%
SARA 41X-13GCONTINENTAL RESOURCES, INC.Active (A)9,239 ft100%
Arley 7-18HSLCONTINENTAL RESOURCES, INC.Active (A)7,965 ft79%

Surveyed Bakken-system laterals with at least 660 ft of plan-view length inside the published footprint. Geometric membership, not a legal assignment; a lateral can cross several units.

Order history

  1. Order 23189Case 20883Designated the spacing unitPETRO- HUNT, LLC
  2. Order 23463Case 21159Established the spacing unit, 1 well allowedXTO ENERGY INC.
  3. Order 23483Case 21179Designated the spacing unitXTO ENERGY INC.
  4. Order 26289Case 23946Established the spacing unit, 2 wells allowedXTO ENERGY INC.
  5. Order 27382Case 24990Pooled all interests in the unitXTO ENERGY INC.

Facts extracted from signed NDIC orders whose land description covers this footprint; machine-extracted and not human-reviewed. A stated allowance is what that order allowed, not proof that it governs today.

Overlapping units

7 other units share a surveyed well with this one; overlapping units are not additive.